Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 189

different models, If they are

Page 189 highlights

6-62 Compaq ProLiant 8000 Servers Maintenance and Service Guide Table 6-16 ADU Diagnostic Messages continued Message Description System board is unable to identify which slots the controllers are in. Slot indicator on system board is not working correctly. Firmware recognizes both controllers as being installed in the same slot. The redundant controllers installed are not the same model. SOLUTION: Power down the system and verify that the redundant controllers are different models. If they are different models, replace the other controller with the same model as this one. This controller can't see the drives but the other controller can ADU detected two different controller models installed in a redundant controller configuration. This is not supported, and one or both controllers may not be operating properly. The other controller in the redundant controller configuration can recognize the drives, but this controller cannot. Recommended Action 1. Make sure both controllers are fully seated in their slots. If the problem persists, this might indicate a controller problem or a system board problem. 2. Remove one of the controllers in the configuration and see if the remaining controller generates a Power-On Self-Test (POST) message. 3. Move the remaining controller to the other slot to see if it still generates a POST message. 4. Repeat these steps with the other controller. If both controllers give POST messages in one slot but not the other, it is a system board problem. If one of the controllers gives POST messages and the other controller does not, replace the controller that is giving the POST messages. Contact a Compaq authorized service provider for any warranty replacements. Use the same controller models for redundant controller configurations. Resolve any other errors and then rerun ADU. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215

6-62
Compaq ProLiant 8000 Servers Maintenance and Service Guide
Table 6-16
ADU Diagnostic Messages
continued
Message
Description
Recommended Action
System board is
unable to identify
which slots the
controllers are
in.
Slot indicator on system board is not
working correctly. Firmware
recognizes both controllers as being
installed in the same slot.
1.
Make sure both controllers are fully seated
in their slots.
If the problem persists, this might indicate
a controller problem or a system board
problem.
2.
Remove one of the controllers in the
configuration and see if the remaining
controller generates a Power-On Self-Test
(POST) message.
3.
Move the remaining controller to the other
slot to see if it still generates a POST
message.
4.
Repeat these steps with the other
controller.
If both controllers give POST messages in one
slot but not the other, it is a system board
problem. If one of the controllers gives POST
messages and the other controller does not,
replace the controller that is giving the POST
messages. Contact a Compaq authorized
service provider for any warranty replacements.
The redundant
controllers
installed are not
the same model.
SOLUTION:
Power down the
system and
verify that the
redundant
controllers are
different models.
If they are
different models,
replace the other
controller with
the same model
as this one.
ADU detected two different controller
models installed in a redundant
controller configuration. This is not
supported, and one or both
controllers may not be operating
properly.
Use the same controller models for redundant
controller configurations.
This controller
can
t see the
drives but the
other controller
can
The other controller in the redundant
controller configuration can
recognize the drives, but this
controller cannot.
Resolve any other errors and then rerun ADU.
continued