Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 153
Array Drive Failure., Slot X Drive
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 153 highlights
6-26 Compaq ProLiant 8000 Servers Maintenance and Service Guide Table 6-2 POST Error Messages continued Error Code Audible Beeps 1782-Disk Controller None Failure 1783-Slot X Drive None Array Controller Failure 1784-Slot X Drive None Array Drive Failure. The following SCSI drive(s) should be replaced: SCSI Port Y: SCSI ID Z: Probable Source of Problem Hard disk drive circuitry error detected. ROM installation problem or array accelerator board problem detected. Defective drive and/or cables detected. Recommended Action Run Compaq Diagnostics. Replace failed assembly as indicated. If this message displays immediately following a ROM installation, the ROM is defective or not installed properly.Check to see if the array accelerator board is attached properly. Check that the array controller is firmly inserted in its slot. Try upgrading the System ROM. Otherwise, replace the Smart Array Controller. Check for loose cables. Replace defective drive X and/or cable(s). continued