Compaq ProLiant 8000 ProLiant 8000 Servers Maintenance and Service Guide - Page 177
Otherwise, run the System Configuration Utility.
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 177 highlights
6-50 Compaq ProLiant 8000 Servers Maintenance and Service Guide Table 6-16 ADU Diagnostic Messages continued Message Description Error occurred reading RIS copy from SCSI Port X Drive ID X An error occurred while ADU was trying to read the reserve information sector (RIS) from this drive. FYI: Drive (bay) X is non-Compaq supplied The installed drive was not supplied by Compaq. Identify controller data did not match with NVRAM The identify controller data from the array controller did not match the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. It could also occur if the firmware on the controller has been upgraded and the System Configuration Utility was not run. Identify logical drive data did not match with NVRAM The identify unit data from the array controller did not match with the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. Insufficient adapter resources The adapter does not have sufficient resources to perform post-write operations to the array accelerator board. Drive rebuild may be occurring. Inter-controller link connection could not be established Unable to communicate over the link connecting the redundant controllers Less than 75% batteries at sufficient voltage The operation of array accelerator board has been disabled due to less than 75% of battery packs being at sufficient voltage level. Less than 75% batteries at sufficient voltage. Battery pack X below reference voltage. Battery pack on array accelerator is below required voltage levels. Recommended Action Compaq stores the hard drive configuration information in the RIS. If there were multiple errors, this drive may need to be replaced. If problems exist with this drive, replace it with a Compaq drive. Run the Inspect Utility to check the controller identification data. If the firmware version field is the only difference between the controller and nonvolatile RAM data, this is not a problem. Otherwise, run the System Configuration Utility. Run the System Configuration Utility to configure the controller and nonvolatile RAM. Operate the system without the array accelerator board until the drive rebuild completes. Make sure both controllers are using the same hardware and firmware revisions. If one controller failed, replace it. Allow sufficient time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the array accelerator board. Allow sufficient time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the array accelerator board. continued