Dell DR4000 Administrator Guide - Page 92
maintenance --hardware --reinit_nvram, NVRAM Field Replacement
View all Dell DR4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
FILE LOCATION: C:\Users\bruce_wylie\Desktop\Dell Docs\~Sidewinder_Docs_DR4000\FRAME_Conversion_DR4000_AdminGuide\~DR4000_AG_F During Maintenance mode, the DR4000 system determines, detects, and repairs the data loss. During the system reboot process, it ensures that no valuable data remains on the NVRAM. NVRAM Field Replacement Whenever NVRAM is replaced in the field, ensure that the following procedure is observed: 1 Verify that the DR4000 system software detects the NVRAM as new to the system. 2 Enter the following DR4000 system CLI command: maintenance --hardware --reinit_nvram This command initializes the NVRAM, creates new partitions, and updates information used internally by the DR4000 system software. 3 Verify that the DR4000 system enters its Maintenance mode. If properly initialized, the DR4000 system enters its Maintenance mode. The filesystem checker examines every blockmap and datastore to determine how much data was lost due to the failed NVRAM. DELL CONFIDENTIAL - PRELIMINARY 1/10/12 - FOR PROOF ONLY 84 Using the DR4000 System Support Options