Dell PowerEdge C6105 Hardware Owner's Manual - Page 50

Option, Description, Immediate, Power Off, Enabled, Disabled

Page 50 highlights

Option Set BMC LAN Configuration Description Inputs for Set LAN Configuration command. Each item in this group may take considerable amount of time. Remote Access Configuration Configures Remote Access. Restore on AC Power Loss System action to take on AC power loss recovery. (Power Off default) Power Staggering AC Recovery (Immediate default) Power On Delay (user defined) View BMC System Event Log Clear BMC System Event Log Event Logging (Enabled default) Configures power recovery behavior. This item only can be seen when "Remote on AC Power Loss" be selected in "Power On" or "Last State". Configures time for power on delay, the setting range of delay time is 0˜255sec. View all events in the BMC Event Log. It will take a max. of 15 seconds to read all BMC SEL records. Clears all events in the BMC Event Log. Enables or disables BIOS to log system events to BMC, errors include ECC/PCI/PCI-E/HT...etc. NMI on Error (Disabled default) Enables or disables BIOS to generate NMI when uncorrectable errors occur. 50 | Using the System Setup Program

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

50
|
Using the System Setup Program
Option
Description
Set BMC LAN
Configuration
Inputs for Set LAN Configuration command.
Each item in this group may take considerable
amount of time.
Remote Access
Configuration
Configures Remote Access.
Restore on AC Power Loss
(
Power Off
default)
System action to take on AC power loss recovery.
Power Staggering AC
Recovery
(
Immediate
default)
Configures power recovery behavior.
This item only can be seen when “Remote on AC
Power Loss” be selected in “Power On” or “Last
State”.
Power On Delay
(user defined)
Configures time for power on delay, the setting
range of delay time is 0˜255sec.
View BMC System Event
Log
View all events in the BMC Event Log. It will
take a max. of 15 seconds to read all BMC SEL
records.
Clear BMC System Event
Log
Clears all events in the BMC Event Log.
Event Logging
(
Enabled
default)
Enables or disables BIOS to log system events to
BMC, errors include ECC/PCI/PCI-E/HT…etc.
NMI on Error
(
Disabled
default)
Enables or disables BIOS to generate NMI when
uncorrectable errors occur.