Dell PowerEdge C6105 Hardware Owner's Manual - Page 65
Power Supplies
View all Dell PowerEdge C6105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Power Supplies NOTE: The following table lists the maximum supported configuration where power supply redundancy is guaranteed. NOTE: Configurations higher than indicated in the table may change the power supply mode to non-redundant. In non-redundant mode if the power requirement exceeds the installed system power capacity, the BIOS will throttle the CPUs. Also, if CPU Power Capping is enabled, then CPU throttling occurs on configurations that exceed the cap value. Table 3-1. PSU and System Board Support Matrix PSU 1400W 1100W 750W 470W Two System Boards Full configuration* Full configuration* Up to two 95W processors / MLB, two hard drives / MLB, and four memory modules / MLB Up to two 35W processors / MLB, up to one hard drives / MLB, and three memory modules / MLB Four System Boards Up to two 95W processors / MLB, two hard drives / MLB, and four memory modules / MLB Up to two 65W processors / MLB, one hard drives / MLB, and six memory modules / MLB N/A N/A Installing System Components | 65