Dell PowerEdge R540 EMC Installation and Service Manual - Page 110

Table 48. Riser configurations: No RSR - 1 CPU, The expansion-card slots are not hot-swappable.

Page 110 highlights

NOTE: The expansion-card slots are not hot-swappable. The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card priority and slot priority order. Table 48. Riser configurations: No RSR - 1 CPU Card Type LOM riser ; 2x1G BCM5720L (FXN) Slot Priority 1 Maximum number of cards 1 LOM riser ; 2x10G BCM57416 (BASeT/SFP 1 1 +) (FXN) PCIe SSD PCIe Card (Samsung) 5 1 Card,Network (Broadcom/INTEL/ 5 1 Mellanox/Solarflare) Card,Controller (EMULEX/QLOGIC/) 5 1 Intel OPA NIC (Intel OPA) 5 1 BOSS M.2 (SATA) (Dell) 5 1 Card,Network (Broadcom/INTEL) 6, 5 2 PERC9.14G/PERC10 (FXN) Integrated Slot 1 RAID - PERC9.14G/PERC10 (Internal) Integrated Slot 1 (Dell) Table 49. Riser configurations: No RSR - 2 CPU Card type Slot priority LOM riser ; 2x1G BCM5720L (FXN) 1 LOM riser ; 2x10G BCM57416 (BASeT/SFP 1 +) (FXN) Card,Network (Broadcom/INTEL/ 4, 5 Mellanox/Solarflare) Card,Controller (EMULEX/QLOGIC) 4, 5 Intel OPA NIC (Intel OPA) 4, 5 BOSS M.2 (SATA) (Dell) 4, 5 Card,Network (Braodcom/INTEL) 6, 5, 4 PERC9.14G/PERC10 (FXN) Integrated Slot RAID - PERC9.14G/PERC10 (Internal) (Dell) Integrated Slot Maximum number of cards 1 1 2 2 2 2 3 1 1 Table 50. Riser configurations: FH - 1 CPU and 2 CPU Card type Slot priority LOM riser ; 2x1G BCM5720L (FXN) 1 LOM riser ; 2x10G BCM57416 (BASeT/SFP 1 +) PERC9.14G/PERC10 (FXN) 2 RAID - PERC10 (External) (Dell) 2 PCIe SSD PCIe Card (Samsung) 2 Maximum number of cards 1 1 1 1 1 110 Installing and removing system components

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175

NOTE:
The expansion-card slots are not hot-swappable.
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with
the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card
priority and slot priority order.
Table 48. Riser configurations: No RSR - 1 CPU
Card Type
Slot Priority
Maximum number of cards
LOM riser ; 2x1G BCM5720L (FXN)
1
1
LOM riser ; 2x10G BCM57416 (BASeT/SFP
+) (FXN)
1
1
PCIe SSD PCIe Card (Samsung)
5
1
Card,Network (Broadcom/INTEL/
Mellanox/Solarflare)
5
1
Card,Controller (EMULEX/QLOGIC/)
5
1
Intel OPA NIC (Intel OPA)
5
1
BOSS M.2 (SATA) (Dell)
5
1
Card,Network (Broadcom/INTEL)
6, 5
2
PERC9.14G/PERC10 (FXN)
Integrated Slot
1
RAID - PERC9.14G/PERC10 (Internal)
(Dell)
Integrated Slot
1
Table 49. Riser configurations: No RSR - 2 CPU
Card type
Slot priority
Maximum number of cards
LOM riser ; 2x1G BCM5720L (FXN)
1
1
LOM riser ; 2x10G BCM57416 (BASeT/SFP
+) (FXN)
1
1
Card,Network (Broadcom/INTEL/
Mellanox/Solarflare)
4, 5
2
Card,Controller (EMULEX/QLOGIC)
4, 5
2
Intel OPA NIC (Intel OPA)
4, 5
2
BOSS M.2 (SATA) (Dell)
4, 5
2
Card,Network (Braodcom/INTEL)
6, 5, 4
3
PERC9.14G/PERC10 (FXN)
Integrated Slot
1
RAID - PERC9.14G/PERC10 (Internal)
(Dell)
Integrated Slot
1
Table 50. Riser configurations: FH - 1 CPU and 2 CPU
Card type
Slot priority
Maximum number of cards
LOM riser ; 2x1G BCM5720L (FXN)
1
1
LOM riser ; 2x10G BCM57416 (BASeT/SFP
+)
1
1
PERC9.14G/PERC10 (FXN)
2
1
RAID - PERC10 (External) (Dell)
2
1
PCIe SSD PCIe Card (Samsung)
2
1
110
Installing and removing system components