Dell PowerEdge R540 EMC Installation and Service Manual - Page 80
Installing cooling fan
![]() |
View all Dell PowerEdge R540 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
Figure 34. Removing cooling fan Next steps 1. Installing cooling fan on page 80. 2. Installing the internal PERC riser on page 84 3. Installing the air shroud on page 77 4. Follow the procedure listed in After working inside your system on page 67. Installing cooling fan The procedure for installing standard and high performance fans are identical. Prerequisites 1. Follow the safety guidelines listed in Safety instructions on page 66. 2. Follow the procedure listed in Before working inside your system on page 67. 3. Removing the air shroud on page 75 4. Removing the internal PERC riser on page 82 5. Remove the power cable. 6. Move the cables out of the way to access the cooling fan cable connector on the system board. Steps 1. Holding the release tab blue touch point, place the cooling fan into the cooling fan cage. 2. Route the cooling fan cable and connect it to the connector on the system board. 80 Installing and removing system components
![](/manual_guide/products/dell-poweredge-r540-emc-installation-service-manual-665d651/80.png)