Dell PowerEdge R540 EMC Installation and Service Manual - Page 36
Standard operating temperature, Expanded operating temperature
View all Dell PowerEdge R540 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Table 26. Relative humidity specifications (continued) Relative humidity Specifications Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point. Table 27. Maximum vibration specifications Maximum vibration Operating Storage Table 28. Maximum shock specifications Maximum shock Operating Storage Specifications 0.26 Grms at 5 Hz to 350 Hz (all operation orientations). 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). Specifications Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms. Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. Table 29. Maximum altitude specifications Maximum altitude Operating Storage Specifications 30482000 m (10,0006560 ft) 12,000 m (39,370 ft) Table 30. Operating temperature derating specifications Operating temperature derating Specifications Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). 35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). 40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). Standard operating temperature Table 31. Standard operating temperature specifications Standard operating temperature Specifications Continuous operation (for altitude less than 950 m or 3117 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. ft) Expanded operating temperature Table 32. Expanded operating temperature specifications Expanded operating temperature Specifications Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C to 40°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. 36 Technical specifications