Table 28. Maximum shock specifications Maximum shock Operating Storage Specifications Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms. Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. Table 29. Maximum altitude specifications Maximum altitude Operating Storage Specifications 3048 m (10,000 ft) 12,000 m (39,370 ft) Table 30. Operating temperature de-rating specifications Operating temperature de-rating Specifications Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). 35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). 40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). Standard operating temperature Table 31. Standard operating temperature specifications Standard operating temperature Specifications Continuous operation (for altitude less than 950 m or 3117 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. ft) Expanded operating temperature Table 32. Expanded operating temperature specifications Expanded operating temperature Specifications Continuous operation 5°C-40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C- 35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. For temperatures between 35°C-40°C, de-rate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). ≤ 1% of annual operating hours -5°C-45°C at 5% to 90% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C- 35°C), the system can operate down to -5°C or up to 45°C for a maximum of 1% of its annual operating hours. For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). NOTE: When operating in the expanded temperature range, system performance may be impacted. 38 Technical specifications
![](/manual_guide/products/dell-poweredge-r640-emc-poweredge-r640-installation-service-manual-aa74b7c/38.png)