Dell PowerEdge R830 Integrated Remote Access Controller 8 Version 2.70.70.70 U - Page 191

Viewing storage device topology, Managing physical disks

Page 191 highlights

Viewing storage device topology You can view the hierarchical physical containment view of the key storage components, that is, a list of controllers, enclosures connected to the controller and a link to the physical disk contained in each enclosure. The physical disks attached directly to the controller are also displayed. To view the storage device topology, go to Overview > Storage > Topology. The Topology page displays the hierarchical representation of the storage components in the system. Click the links to view the respective component details. Managing physical disks You can perform the following for physical disks: • View physical disk properties. • Assign or unassign physical disk as a global hot-spare. • Convert to RAID capable disk. • Convert to non-RAID disk. • Blink or unblink the LED. Related concepts Inventorying and monitoring storage devices Assigning or unassigning physical disk as global hot spare Assigning or unassigning physical disk as global hot spare A global hot spare is an unused backup disk that is part of the disk group. Hot spares remain in standby mode. When a physical disk that is used in a virtual disk fails, the assigned hot spare is activated to replace the failed physical disk without interrupting the system or requiring your intervention. When a hot spare is activated, it rebuilds the data for all redundant virtual disks that were using the failed physical disk. NOTE: From iDRAC v2.30.30.30 or later, you can add global hot spares when virtual disks are not created. You can change the hot spare assignment by unassigning a disk and choosing another disk as needed. You can also assign more than one physical disk as a global hot spare. Global hot spares must be assigned and unassigned manually. They are not assigned to specific virtual disks. If you want to assign a hot spare to a virtual disk (it replaces any physical disk that fails in the virtual disk), then see Assigning or unassigning dedicated hot spares. When deleting virtual disks, all assigned global hot spares may be automatically unassigned when the last virtual disk associated with the controller is deleted. If you reset the configuration, the virtual disks are deleted and all the hot spares are unassigned. You must be familiar with the size requirements and other considerations associated with hot spares. Before assigning a physical disk as a global hot spare: • Make sure that Lifecycle Controller is enabled. • If there are no disk drives available in ready state, insert additional disk drives and make sure that the drives are in ready state. • If no virtual disks are present, create at least one virtual disk. • If physical disks are in non-RAID mode convert them to RAID mode using iDRAC interfaces such as iDRAC web interface, RACADM, or WSMAN, or . If you have assigned a physical disk as a global hot spare in Add to Pending Operation mode, the pending operation is created but a job is not created. Then, if you try to unassign the same disk as global hot spare, the assign global hot spare pending operation is cleared. If you have unassigned a physical disk as a global hot spare in Add to Pending Operation mode, the pending operation is created but a job is not created. Then, if you try to assign the same disk as a global hot spare, the unassign global hot spare pending operation is cleared. Assigning or unassigning global hot spare using web interface To assign or unassign a global hot spare for a physical disk drive: 1. In the iDRAC web interface, go to Overview > Storage > Physical Disks > Setup. Managing storage devices 191

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298

Viewing storage device topology
You can view the hierarchical physical containment view of the key storage components, that is, a list of controllers, enclosures connected
to the controller and a link to the physical disk contained in each enclosure. The physical disks attached directly to the controller are also
displayed.
To view the storage device topology, go to
Overview
>
Storage
>
Topology
. The
Topology
page displays the hierarchical
representation of the storage components in the system.
Click the links to view the respective component details.
Managing physical disks
You can perform the following for physical disks:
View physical disk properties.
Assign or unassign physical disk as a global hot-spare.
Convert to RAID capable disk.
Convert to non-RAID disk.
Blink or unblink the LED.
Related concepts
Inventorying and monitoring storage devices
Assigning or unassigning physical disk as global hot spare
Assigning or unassigning physical disk as global hot spare
A global hot spare is an unused backup disk that is part of the disk group. Hot spares remain in standby mode. When a physical disk that is
used in a virtual disk fails, the assigned hot spare is activated to replace the failed physical disk without interrupting the system or requiring
your intervention. When a hot spare is activated, it rebuilds the data for all redundant virtual disks that were using the failed physical disk.
NOTE:
From iDRAC v2.30.30.30 or later, you can add global hot spares when virtual disks are not created.
You can change the hot spare assignment by unassigning a disk and choosing another disk as needed. You can also assign more than one
physical disk as a global hot spare.
Global hot spares must be assigned and unassigned manually. They are not assigned to specific virtual disks. If you want to assign a hot
spare to a virtual disk (it replaces any physical disk that fails in the virtual disk), then see
Assigning or unassigning dedicated hot spares
.
When deleting virtual disks, all assigned global hot spares may be automatically unassigned when the last virtual disk associated with the
controller is deleted.
If you reset the configuration, the virtual disks are deleted and all the hot spares are unassigned.
You must be familiar with the size requirements and other considerations associated with hot spares.
Before assigning a physical disk as a global hot spare:
Make sure that Lifecycle Controller is enabled.
If there are no disk drives available in ready state, insert additional disk drives and make sure that the drives are in ready state.
If no virtual disks are present, create at least one virtual disk.
If physical disks are in non-RAID mode convert them to RAID mode using iDRAC interfaces such as iDRAC web interface, RACADM, or
WSMAN, or <CTRL+R>.
If you have assigned a physical disk as a global hot spare in Add to Pending Operation mode, the pending operation is created but a job is
not created. Then, if you try to unassign the same disk as global hot spare, the assign global hot spare pending operation is cleared.
If you have unassigned a physical disk as a global hot spare in Add to Pending Operation mode, the pending operation is created but a job
is not created. Then, if you try to assign the same disk as a global hot spare, the unassign global hot spare pending operation is cleared.
Assigning or unassigning global hot spare using web interface
To assign or unassign a global hot spare for a physical disk drive:
1.
In the iDRAC web interface, go to
Overview
>
Storage
>
Physical Disks
>
Setup
.
Managing storage devices
191