Dell PowerEdge T110 Hardware Owner's Manual - Page 25
MEMTEST lane, failure, detected on, address, value - support
View all Dell PowerEdge T110 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Message Causes Corrective Actions Memory odd/even logic failure at address, read value expecting value. Faulty or improperly See "Troubleshooting System installed memory modules. Memory" on page 113. Memory write/read failure at address, read value expecting value. Faulty or improperly See "Troubleshooting System installed memory modules. Memory" on page 113. Memory set to minimum frequency. The memory frequency may be intentionally set lower for power conservation. If not an intentional setting, check any other system messages for possible causes. The current memory configuration may support only the minimum frequency. Ensure that your memory configuration supports the higher frequency. See "General Memory Module Installation Guidelines" on page 80. Memory tests terminated by keystroke. POST memory test was Information only. terminated by pressing the spacebar. MEMTEST lane failure detected on x. Invalid memory configuration. A mismatched memory module is installed. Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 80. About Your System 25