Dell PowerEdge T110 Hardware Owner's Manual - Page 29
geometry, in rank, count, in size, and geometry, and rank count, Check the Time and Date - memory installation guidelines
View all Dell PowerEdge T110 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Message Causes Corrective Actions The following DIMMs should match in geometry: x,x,... The following DIMMs should match in rank count: x,x,... Invalid memory Ensure that the memory configuration. The modules are installed in a valid specified memory modules configuration. See "General do not match in size, Memory Module Installation number of ranks, or Guidelines" on page 80. number of data lanes. The following DIMMs should match in size: x,x,... The following DIMMs should match in size and geometry: x,x,... The following DIMMs should match in size and rank count: x,x,... Thermal sensor not detected on x. A memory module without Replace the memory module. a thermal sensor is installed See "System Memory" on in the specified memory page 80. slot. Time-of-day clock stopped. Faulty battery or faulty chip. See "Troubleshooting the System Battery" on page 110. Time-of-day not Incorrect Time or Date set - please run settings; faulty system SETUP program. battery. Check the Time and Date settings. See "Using the System Setup Program and UEFI Boot Manager" on page 35. If the problem persists, replace the system battery. See "System Battery" on page 91. About Your System 29