GE 60-806-95R-16Z Installation Instructions - Page 42
Siren Options Menu, Force Armed 0515, Alarm Verify 0516, System Tamper 0517, Immediate Trouble Beeps
UPC - 046188090938
View all GE 60-806-95R-16Z manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Force Armed (0515) Reporting-Partition 1 (Default=off) This setting determines whether or not the panel reports to the central monitoring station when a user force arms the system. Force Armed occurs if the user presses BYPASS when arming the system with open sensors/zones protesting. Note Auto Force Armed always reports to the central monitoring station. Auto Force Armed occurs if the user does not press BYPASS when arming the system with open sensors/zones protesting and the siren time expires. ¾ To turn Force Armed off or on: 1. With the display showing FORCE ARMED OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting. 2. Press ƒ and the display shows the new setting. For UL Listed systems, Force Armed must be turned off. Alarm Verify (0516) Reporting-Partition 1 (Default=off) This setting determines whether the panel reports to the central monitoring station after a single sensor/zone trip (off) or waits for a second trip before reporting (on). The second trip must be a different sensor and occur within 4 minutes of the first trip. This setting affects sensors/zones learned into groups 10 through 20. If Alarm Verify is set to on, group 18 responds the same as group 17. See "Appendix A, Table A.3: Sensor Group Characteristics." Note For UL Listed systems, Alarm Verify must be turned off. ¾ To turn Alarm Verify off or on: 1. With the display showing ALARM VERIFY OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting. 2. Press ƒ and the display shows the new setting. System Tamper (0517) Reporting-Partition 1 (Default=off) This setting determines the following: • Whether or not the armed system goes into alarm if several incorrect access codes (40 consecutive keystrokes) are entered. • Whether or not the panel reports to the central station if a bus device stops communicating with the panel. • Whether or not the panel reports to the central station if an RF sensor (non fire) is tampered with. Tamper on fire sensors will always be reported to the central station. Note For UL Listed systems, System Tamper must be turned on. ¾ To change the System Tamper setting: 1. With the display showing SYSTEM TAMPER OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting. 2. Press ƒ and the display shows the new setting. Siren Options Menu The SIREN OPTIONS menu lets you set up siren operation and supervision. The following describes how to program the siren option settings that appear under GLOBAL. Immediate Trouble Beeps (0600) This setting determines whether the panel activates trouble beeps immediately (on) once a wireless device supervisory condition is detected, or only if the condition exists at panel supervisory time (off). Refer to TIMERS-GLOBAL-SUPERVISORY TIME. Note For UL Listed systems, this feature must be on. Siren Options-Global (Default=off) ¾ To turn Immediate Trouble Beeps off or on: 1. With the display showing IMMEDIATE BEEPS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting. 2. Press ƒ and the display shows the new setting. 37 Programming the Panel