GE 60-806-95R-16Z Installation Instructions - Page 55
Troubleshooting
UPC - 046188090938
View all GE 60-806-95R-16Z manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Troubleshooting This section describes what to do if you experience problems with system operation. Topics are in alphabetical for easy reference. Feature Problem Action/Solution Access Code Customer cannot remember access code(s). 1. Check your records to see if you have the customer's access code(s) on file. 2. Verify the access code(s) using the Downloader. 3. Clear memory and reprogram the panel locally. Note Clearing panel memory deletes factory zone programming. Installer cannot remember install code. 1. Check your records to see if you have the install code on file. 2. Verify the install code using the Downloader. 3. Use the Dealer Code to enter program mode and view the installer code. 4. Call Technical Support for assistance. Installer cannot remember dealer code 1. Check your records to see if you have the dealer code on file. 2. Verify the dealer code using the Downloader. 3. Call Technical Support for assistance. Alphanumeric Touchpads Display shows all Touchpad is not connected to panel bus terminals or is wired incorrectly. Check and correct wiring. Display is blank. 1. Check that panel is powered up. 2. Check for touchpad power and/or bus miswiring, opens, or shorts. 3. Check touchpad brightness setting (see the user programming OPTIONS menu). Touchpad buttons don't beep when pressed. 1. Check for touchpad power and/or bus miswiring, opens, or shorts. 2. Check that key beeps option is set to on (see the ACCESSORY MODULES-BUS DEVICES menu). Arming and Disarming System protests and won't arm. 1. If arming to level 2, make sure all monitored perimeter doors and windows are closed. 2. If arming to level 3, make sure all perimeter and interior sensors are closed. 3. Press STATUS for an indication of the problem. System won't disarm. 1. Disarming using incorrect code. Enter correct code. 2. Access code is not programmed or set up in user programming to disarm system. 3. Wireless touchpad is not learned into system or hardwire touchpad is not communicating to panel. Check installer programming for learned touchpads. 4. The installer code is being used to disarm the system. The system is designed not to dis- arm using the installer code. Use a regular or system master code to disarm the system. Bypassing Touchpad indicates Invalid when you attempt to bypass a sensor. 1. Sensor is already bypassed. 2. Attempting to bypass a 24-hour sensor that cannot be bypassed (group 26 fire sensors). 3. Sensor is not active in the current arming level. System cancels sensor bypass when you try to arm to level 2 or 3. Sensor is being bypassed before arming to 2-STAY or 3-AWAY. Arm to the desired level before bypassing a sensor. Central Station/Pager Reporting Troubleshooting 50