GE 60-806-95R-16Z Installation Instructions - Page 6

About This, Manual, Special, Installation, Requirements - security

Page 6 highlights

About This Manual Special Installation Requirements This manual provides information for planning, installing, programming, and testing this security system. When necessary, this manual refers you to other documentation included with compatible devices. Planning sheets are included for you to record hardware layout and software programming settings. This security system can be used as a wire warning system, an intrusion alarm system, an emergency notification system, or any combination of the three. Some installations may require configurations dictated by city or state codes, insurance, or Underwriter's Laboratories (UL). This section describes the various component and configuration listings. UL Listed Systems This section describes the requirements for UL Listed systems. Basic System • Control Panel (60-806, 60-806-95R) • Backup Battery, 12 VDC, 4 AH (60-681) • SuperBus 2000 2x16 LCD Touchpad (60-746-01), SuperBus 2000 Fixed Display Touchpad (60-820), SuperBus 2000 2x20 LCD Touchpad (60-803), or SuperBus 2000 2x20 VFD Touchpad (60-804) • Standard Class II 16.5 VAC, 25 VA Power Transformer; manufacturer-Tech Electro Ind, Inc. Part No. 48A0164 (60-822) • 15-Watt, Dual Tone Siren (13-469) or Hardwire Siren (13-046) Household Burglary Alarm System Unit (UL 1023) Basic system, plus: • Hardwire Magnetic Contact (Sentrol part # 1075-N or 1038T-N) or Wireless Learn Mode Door/Window Sensor (60-362), Wireless Learn Mode PIR Motion Sensor (60-703-95, 60-511, or 60-639) • IMMEDIATE TROUBLE BEEPS set to on • UL 98 OPTIONS set to on • RECEIVER FAILURE set to on • EXIT DELAY set to 60 seconds or less • QUICK EXIT set to off • SIREN TIMEOUT set to 4 minutes or more • SIREN VERIFY set to on • ENTRY DELAY set to 45 seconds or less • RF TX TIMEOUT set to 24 hours • EXTENDED DELAY set to off • TWO TRIP ERROR set to off • ALARM VERIFY set to off • DISABLE TROUBLE BEEPS set to off • SYSTEM TAMPER set to on Household Fire Warning System (UL 985) Basic system plus: 1 About This Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

About This Manual
1
About This
Manual
This manual provides information for planning, installing, programming, and testing
this security system. When necessary, this manual refers you to other documentation
included with compatible devices.
Planning sheets are included for you to record hardware layout and software program-
ming settings.
Special
Installation
Requirements
This security system can be used as a wire warning system, an intrusion alarm system,
an emergency notification system, or any combination of the three.
Some installations may require configurations dictated by city or state codes, insur-
ance, or Underwriter’s Laboratories (UL). This section describes the various compo-
nent and configuration listings.
UL Listed Systems
This section describes the requirements for UL Listed systems.
Basic System
Control Panel (60-806, 60-806-95R)
Backup Battery, 12 VDC, 4 AH (60-681)
SuperBus 2000 2x16 LCD Touchpad (60-746-01), SuperBus 2000 Fixed Display
Touchpad (60-820), SuperBus 2000 2x20 LCD Touchpad (60-803), or SuperBus
2000 2x20 VFD Touchpad (60-804)
Standard Class II 16.5 VAC, 25 VA Power Transformer; manufacturer—Tech Elec-
tro Ind, Inc. Part No. 48A0164 (60-822)
15-Watt, Dual Tone Siren (13-469) or Hardwire Siren (13-046)
Household Burglary Alarm System Unit (UL
1023
)
Basic system, plus:
Hardwire Magnetic Contact (Sentrol part # 1075-N or 1038T-N) or Wireless Learn
Mode Door/Window Sensor (60-362), Wireless Learn Mode PIR Motion Sensor
(60-703-95, 60-511, or 60-639)
IMMEDIATE TROUBLE BEEPS set to on
UL 98 OPTIONS set to on
RECEIVER FAILURE set to on
EXIT DELAY set to 60 seconds or less
QUICK EXIT set to off
SIREN TIMEOUT set to 4 minutes or more
SIREN VERIFY set to on
ENTRY DELAY set to 45 seconds or less
RF TX TIMEOUT set to 24 hours
EXTENDED DELAY set to off
TWO TRIP ERROR set to off
ALARM VERIFY set to off
DISABLE TROUBLE BEEPS set to off
SYSTEM TAMPER set to on
Household Fire Warning System (UL 985)
Basic system plus: