Installation 3-21 1 5 4 3 2 SHR-1715 Figure 3-12. Expansion unit SCSI connectors and cables (fast wide SCSI shown) Table 3-8 Expansion Unit SCSI connectors and Cables (Fast Wide SCSI Shown) Figure Legend 1 2 3 4 5 Description Pass-through motor cable connector Power cable Robotics cables to Base Modules SCSI cable Diagnostic connector PTM Motor Cable The PTM motor cable is 36 in (91 cm) long and has a male DB-15 connector on each end. Connect the cable from the connector on the motor housing of the PTM to the motor connector on the Expansion Unit.
![](/manual_guide/products/hewlettpackard-sw-tl881-dlt-minilib1-compaq-storageworks-tl881tl891-family-minilibrary-reference-guide-2000-0b2e4a1/102.png)
Installation
3-21
SHR-1715
5
1
4
3
2
Figure 3-12.
Expansion unit SCSI connectors and cables (fast wide SCSI
shown)
Table 3-8
Expansion Unit SCSI connectors and Cables
(Fast Wide SCSI Shown)
Figure Legend
Description
1
Pass-through motor cable connector
2
Power cable
3
Robotics cables to Base Modules
4
SCSI cable
5
Diagnostic connector
PTM Motor Cable
The PTM motor cable is 36 in (91 cm) long and has a male DB-15 connector
on each end. Connect the cable from the connector on the motor housing of the