HP SW TL881 DLT Mini-Lib/1 Compaq StorageWorks TL881/TL891 Family MiniLibrary - Page 161
Table 6-9, Boot Error Codes Bxxx, Slave 3 Ch Flash Err
![]() |
View all HP SW TL881 DLT Mini-Lib/1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 161 highlights
Diagnostics and Troubleshooting 6-19 Table 6-8 Intermodule Error Codes (6xxx) continued FSC Message 6044 Invalid Com Blk Type 6045 Command Overlap 6046 No Pkts To Send 6047 Invalid Direction 6048 Master Pkt ID Bad 6060 Slave 3 Ch Init Err 6061 Slave 3 Ch Sync Err 6062 Slave 3 Ch Flash Err Description A Slave inter-module process received a packet from the Status/Message queue, but the packet's CommBlock type was invalid. A Slave inter-module process received a Command from the Master inter-module process, but a previously issued command is still being executed. A Slave inter-module process has been requested to send a packet to the Master inter-module process, but the Slave inter-module process has no packets to send. A Slave inter-module process has received a direction control byte from the Master inter-module process, but the direction control byte is invalid. An error occurred during the 3 Ch slave module initialization. An error occurred attempting to sync with the 3 Ch slave module. An error occurred attempting to flash the 3 Ch slave module. Table 6-9 Boot Error Codes (Bxxx) FSC Message Description B001 Boot ROM CRC Error B002 Boot RAM Test Failed B004 Boot Comm Open Error B005 Boot Novram Error B006 Boot Unused Int B007 Flash Init Error continued
![](/manual_guide/products/hewlettpackard-sw-tl881-dlt-minilib1-compaq-storageworks-tl881tl891-family-minilibrary-reference-guide-2000-0b2e4a1/161.png)