HP SW TL881 DLT Mini-Lib/1 Compaq StorageWorks TL881/TL891 Family MiniLibrary - Page 130

Set Element Base, address assignment The defaults are transport = 0000h, storage element

Page 130 highlights

Configuration 4-7 The following Special Config submenu appears: Mode Pg 1F Length * Short (0x0E) Model Number * Compaq TL89X Press twice to position the next to the TUR Reporting option. Press the Enter button to move down one line to *Standard. Use the to change to Custom and press the Enter button to accept this setting. To return the Base Module to online status, press the Escape button three times. Set Element Base This option lets you set the base addresses of each of the three SCSI elements of the module. In order to identify sources and destinations in commands to the robotics, the Base Module is divided into elements, each of which is assigned a separate designator or element address. The transport element is the robotics mechanism itself; the storage elements are the 10 or 16 slots in the magazine; the transfer elements are the drives. The Base Module reports these settings in response to the SCSI MODE SENSE command, in the element address assignment page. The defaults are transport = 0000h, storage element base = 0001h, transfer element base = 00F0h.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213

Configuration
4-7
The following Special Config submenu appears:
Mode Pg 1F Length
* Short (0x0E)
Model Number
* Compaq TL89X
Press
twice to position the
next to the TUR Reporting option. Press
the
Enter
button to move
down one line to *Standard. Use the
to
change to
Custom and press the
Enter
button to accept this setting. To
return the Base Module to online status, press the
Escape
button
three
times.
Set Element Base
This option lets you set the base addresses of each of the three SCSI elements
of the module. In order to identify sources and destinations in commands to
the robotics, the Base Module is divided into elements, each of which is
assigned a separate designator or element address. The transport element is the
robotics mechanism itself; the storage elements are the 10 or 16 slots in the
magazine; the transfer elements are the drives. The Base Module reports these
settings in response to the SCSI MODE SENSE command, in the element
address assignment page. The defaults are transport = 0000h, storage element
base = 0001h, transfer element base = 00F0h.