Troubleshooting, Removal, and Replacement Understanding Error States Troubleshooting Table 4-1 Partial Availability Conditions Library Status Cause Solution Date and time not The date and time is not set on set the front panel • Set the date and time. (See "Setting the Date and Time" on page 3-21.) Drive(s) not present The library could not detect all the expected drive modules. NOTE: This typically occurs because a drive was physically removed from the library. This may also occur for a brief time during an online drive repair. This condition will persist over a power cycle. If a drive is present in the library: • Power off the library. • Reseat the drive module. • Power on the library. • Contact your service representative. Drive(s) offline Drive(s) taken offline because of the following: • Taken offline from front panel, host computer, or library controller. • Drive(s) failed power-on test. • Drive module board failed power-on test. • Failed serial communication to drive. • Failed to load/unload tape. • Verify that the drive is online. If not, put drive back online from the front panel. • Power cycle the library. • Verify cabling and termination. • Check the error log from the front panel or RMC Web-Based Library Administrator pages for possible causes. • Contact your service representative. Drive(s) online pending Drive(s) are present and powered up, but have outdated firmware. • Update drive firmware. (See page 4-60.) Drive firmware mismatch Drives are present and powered up, but have different revisions of firmware. • Update drive firmware. (See page 4-60.) Drive(s) needs cleaning One or more drives need cleaning. • Clean the drive(s). (See page 217.) Chapter 4 4-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256

Troubleshooting, Removal, and Replacement
Understanding Error States
Chapter 4
4-9
Troubleshooting
Table 4-1
Partial Availability Conditions
Library Status
Cause
Solution
Date and time not
set
The date and time is not set on
the front panel
Set the date and time. (See
Setting the Date and Time
on
page 3-21.)
Drive(s) not
present
The library could not detect all
the expected drive modules.
NOTE:
This typically occurs
because a drive was physically
removed from the library. This
may also occur for a brief time
during an online drive repair.
This condition will persist over a
power cycle.
If a drive is present in the library:
Power off the library.
Reseat the drive module.
Power on the library.
Contact your service
representative.
Drive(s) offline
Drive(s) taken offline because of
the following:
Taken offline from front
panel, host computer, or
library controller.
Drive(s) failed power-on test.
Drive module board failed
power-on test.
Failed serial communication
to drive.
Failed to load/unload tape.
Verify that the drive is online. If
not, put drive back online from
the front panel.
Power cycle the library.
Verify cabling and termination.
Check the error log from the
front panel or RMC Web-Based
Library Administrator pages
for possible causes.
Contact your service
representative.
Drive(s) online
pending
Drive(s) are present and
powered up, but have outdated
firmware.
Update drive firmware. (See
page 4-60.)
Drive firmware
mismatch
Drives are present and powered
up, but have different revisions
of firmware.
Update drive firmware. (See
page 4-60.)
Drive(s) needs
cleaning
One or more drives need
cleaning.
Clean the drive(s). (See page 2-
17.)