HP Xw8400 HP xw8400 Workstation - Service and Technical Reference Guide - Page 139
POST error messages
UPC - 883585271085
View all HP Xw8400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Table 5-18 POST error messages (continued) Screen Message Probable Cause Recommended Action 211-Memory warning condition detected. An unknown issue with one of the DIMMs has been detected. CAUTION: Disconnect AC power from the workstation before reseating or replacing components because there is power to the system board even when the workstation is powered down. 1. Verify proper memory module type. 2. Try another memory socket. 3. Replace memory module if problem persists. 212-Failed Processor. Processor has failed to initialize. CAUTION: Disconnect AC power from the workstation before reseating or replacing components because there is power to the system board even when the workstation is powered down. 1. Reseat the processor in its socket. 2. If the processor does not respond, replace it. 213-Incompatible ECC Memory Module in memory Socket(s). The memory modules in the system are either not all ECC, or not all nonECC. This could also be caused because the DIMM is missing critical SPD information. CAUTION: Disconnect AC power from the workstation before reseating or replacing components because there is power to the system board even when the workstation is powered down. 1. Verify that all memory modules are ECC or nonECC. 2. Replace memory module if problem persists. 214-DIMM Configuration Warning. DIMMs not installed correctly (not paired correctly). Refer to Memory on page 64"Memory" for the correct memory configurations and reseat the DIMMs accordingly. 301-Keyboard Error. Keyboard failure. 1. Reconnect keyboard with workstation powered off. 2. Check the connector for bent or missing pins. 3. Be sure that none of the keys are pressed. 4. Replace keyboard. 303-Keyboard Controller Error. I/O board keyboard controller. CAUTION: Disconnect AC power from the workstation before reseating or replacing components because there is power to the system board even when the workstation is powered down. 1. Reconnect keyboard with workstation powered off. 2. Replace the system board. 304-Keyboard or System Unit Keyboard failure. Error. CAUTION: Disconnect AC power from the workstation before reseating or replacing components because there is power to the system board even when the workstation is powered down. 1. Reconnect the keyboard with workstation powered off. 2. Be sure that none of the keys are pressed. 3. Replace keyboard. 4. Replace system board. 401-Parallel Port 1 Address Assignment Conflict. IRQ address conflicts with another device. Reset the IRQ in the BIOS Setup menu. ENWW POST error messages 129