Icom IC-7200 Instruction Manual - Page 102
Band Voltage Modification
View all Icom IC-7200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
18 BAND VOLTAGE MODIFICATION ■ Band voltage modification If you want to connect an external unit which can be controlled by the band voltage from [ACC] connector, the modification is necessary as at right. The band voltage appears from pin 5 of [ACC] connector after modification (q) is completed, or the regulated 8 V appears from pin 1 of [ACC] connector after modification (w) is completed. Performing this modification is the customer's responsibility. Icom does not guarantee this modification's result. CAUTION: Disconnect the DC power cable from the transceiver before any work on the transceiver. IC-7200's bottom view with RF unit bottom cover is opened. Front panel Bridge these solder pads q BAND • Band voltage generator circuit The below circuit is just for reference. ACC socket of an optional unit GND 7 6 3 1 5 24 8 V 4700 pF External power souce 8 V 100 µH 1.9 MHz VR 4.7 kø 3.5 MHz Rotary switch BAND Diode 100 µH 4700 pF 4.7 kø 4700 pF VR 4.7 kø 7 MHz Open 10 MHz VR 10 kø 14 MHz VR 10 kø 18/21 MHz OR 22 kø 24/28 MHz w 8 V The following band voltage table is for reference only. Please adjust and confirm against the actual operating condition. BAND 1.9 MHz 3.5 MHz 7 MHz 10 MHz 14 MHz 18/21 MHz 24/28 MHz VOLTAGE Non-adjustment 6.1 V 5.1 V Non-adjustment 4.1 V 3.1 V 2.1 V 97