Icom IC-7200 Instruction Manual - Page 93

CONTROL COMMAND, ■ Remote jack (CI-V) information, ◇ CI-V connection example, ◇ Data format

Page 93 highlights

14 CONTROL COMMAND Preamble code (fixed) Controller's default address Transceiver's default address Command number (see table at right) Sub command number (see table at right) BCD code data for frequency or memory number entry End of message code (fixed) ■ Remote jack (CI-V) information D CI-V connection example The transceiver can be connected through an optional CT-17 ci-v level converter to a personal computer equipped with an RS-232C port. The Icom Communication interface-V (CI-V) controls the following functions of the transceiver. Up to four Icom CI-V transceivers or receivers can be connected to a personal computer equipped with an RS-232C port. See p. 82 for setting the CI-V condition using set mode. D Data format The CI-V system can be operated using the following data formats. Data formats differ according to command numbers. A data area is added for some commands. CONTROLLER TO IC-7200 q wert y u FE FE 76 E0 Cn Sc Data area FD 9-15 V DC PC ct-17 IC-7200 OK MESSAGE TO CONTROLLER FE FE E0 76 FB FD Preamble code (fixed) Controller's default address Transceiver's default address OK code (fixed) End of message code (fixed) Preamble code (fixed) Transceiver's default address Controller's default address Command number (see table at right) Sub command number (see table at right) BCD code data for frequency or memory number entry End of message code (fixed) IC-7200 TO CONTROLLER q wert y u FE FE E0 76 Cn Sc Data area FD NG MESSAGE TO CONTROLLER FE FE E0 76 FA FD Preamble code (fixed) Controller's default address Transceiver's default address NG code (fixed) End of message code (fixed) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 88

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

14
88
CONTROL COMMAND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Remote jack (CI-V) information
D
CI-V connection example
The transceiver can be connected through an optional
CT-17
CI
-
V
LEVEL
CONVERTER
to a personal computer
equipped with an RS-232C port. The Icom Communi-
cation interface-V (CI-V) controls the following func-
tions of the transceiver.
Up to four Icom CI-V transceivers or receivers can be
connected to a personal computer equipped with an
RS-232C port. See p. 82 for setting the CI-V condition
using set mode.
D
Data format
The CI-V system can be operated using the following
data formats. Data formats differ according to com-
mand numbers. A data area is added for some com-
mands.
9–15 V DC
PC
ct-17
IC-7200
CONTROLLER TO IC-7200
FE
FE
FE
76
E0
Cn
Sc
Data area
FD
Preamble code (fixed)
Transceiver’s default address
Controller’s default address
Command number
(see table at right)
Sub command number
(see table at right)
BCD code data for frequency or
memory number entry
End of message code (fixed)
OK MESSAGE TO CONTROLLER
FE FE E0 76
FB FD
Preamble code (fixed)
Controller’s default address
Transceiver’s default address
OK code (fixed)
End of message code (fixed)
NG MESSAGE TO CONTROLLER
FE FE E0 76
FA FD
Preamble code (fixed)
Controller’s default address
Transceiver’s default address
NG code (fixed)
End of message code (fixed)
IC-7200 TO CONTROLLER
FE
E0
76
Cn
Sc
Data area
FD
Preamble code (fixed)
Controller’s default address
Transceiver’s default address
Command number
(see table at right)
Sub command number
(see table at right)
BCD code data for frequency or
memory number entry
End of message code (fixed)
q
w
e
r
t
y
u
q
w
e
r
t
y
u