Icom IC-7200 Instruction Manual - Page 80

Band Edge Beep, Beep Level, Beep Level Limit, RF/SQL Control, Meter Peak Hold, Set mode Continued

Page 80 highlights

10 SET MODE ■ Set mode (Continued) Band Edge Beep A beep sounds when an operating frequency enters or exits an amateur band. This function is independent from "Beep" (the confirmation beep) setting as above. on : Band edge beep ON oF : Band edge beep OFF The volume level can be set in "Beep Level" as below. Beep Level This item sets the maximum volume level for the confirmation beep and band edge beep tones from 0% to 100% in 1% steps. When beep tones are set to OFF, this setting has no effect. Beep Level Limit Turn the beep tones output level limiting capability ON and OFF for the confirmation and band edge beep tones. When this item is set to ON, the beep tones are linked to the [AF] control until rotation of the [AF] control reaches to the specified level-further rotation will not increase the volume of the beep tones. on : Beep level is limited with the [AF] control oF : Beep level is linked to the [AF] control RF/SQL Control The [RF/SQL] control can be set as the RF/squelch control, the squelch control only (RF gain is fixed at maximum) or Auto (RF gain control in SSB, CW and RTTY; squelch control in AM). See pgs. 4, 30 for details. rS (RF+SQL) : [RF/SQL] control is set as the RF/squelch control Sq (SQL) : [RF/SQL] control is set as the squelch control At (AUTO) : [RF/SQL] control is set as the RF gain control in SSB, CW and RTTY; squelch control in AM Meter Peak Hold This item turns the meter peak hold function ON or OFF. on : The highest activated segment of the meter remains visible for 0.5 sec. oF : The meter functions normally. 75 ON (default) 50% (default) ON (default) RF +SQL (default) ON (default)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

75
10
SET MODE
Set mode (Continued)
Band Edge Beep
A beep sounds when an operating frequency enters or
exits an amateur band. This function is independent from
“Beep” (the confirmation beep) setting as above.
on : Band edge beep ON
oF : Band edge beep OFF
The volume level can be set in “Beep Level” as below.
ON (default)
Beep Level
This item sets the maximum volume level for the con-
firmation beep and band edge beep tones from 0% to
100% in 1% steps.
When beep tones are set to OFF, this setting has no ef-
fect.
50% (default)
Beep Level Limit
Turn the beep tones output level limiting capability ON
and OFF for the confirmation and band edge beep tones.
When this item is set to ON, the beep tones are linked to
the
[AF]
control until rotation of the
[AF]
control reaches
to the specified level—further rotation will not increase
the volume of the beep tones.
on : Beep level is limited with the
[AF]
control
oF : Beep level is linked to the
[AF]
control
ON (default)
RF/SQL Control
The [RF/SQL] control can be set as the RF/squelch con-
trol, the squelch control only (RF gain is fixed at maxi-
mum) or Auto (RF gain control in SSB, CW and RTTY;
squelch control in AM).
See pgs. 4, 30 for details.
rS (RF+SQL) : [RF/SQL] control is set as the RF/squelch
control
Sq (SQL)
: [RF/SQL] control is set as the squelch
control
At (AUTO)
: [RF/SQL] control is set as the RF gain
control in SSB, CW and RTTY; squelch
control in AM
RF +
SQL (default)
Meter Peak Hold
This item turns the meter peak hold function ON or OFF.
on : The highest activated segment of the meter remains
visible for 0.5 sec.
oF : The meter functions normally.
ON (default)