Icom IC-7200 Instruction Manual - Page 71

■ Programmed scan operation (VFO mode), ■ Memory scan operation (Memory mode

Page 71 highlights

8 SCAN OPERATION ➔ ➔ ■ Programmed scan operation (VFO mode) Programmed scan searches for signals between scan edge memory channels P1 and P2. The default frequencies for these memories are 0.500000 MHz and 29.99999 MHz, respectively. See p. 62 for scan edges programming. q Push V/M to select VFO mode. w Push MODE to select the desired operating mode. • The operating mode can be changed while scanning. e Push TS to select a tuning step. • The tuning step cannot be changed while scanning. (The programmed tuning function can be turned ON or OFF while scanning.) r Set the [RF/SQL] control open or closed. • See the left page for squelch condition. t Push SCAN to start the scan. • " " appears while scanning. y When the scan detects a signal, the scan turns OFF, pauses or ignores it depending on the resume setting and the squelch condition. u To cancel the scan, push SCAN . NOTE: If the same frequencies are programmed into both scan edge memory channels P1 and P2, programmed scan does not start. MODE TS TUNER FILTER SPCH [RF/SQL] NB NR ANF METER V/M 1 1.8 A=/B 2 3.5 SPLIT 3 7 MW 4 10 M-CL 5 14 AGC 6 18 COMP271 . RIT GENE SCAN 8 24 MNF 0 50 VOX 9 28 F-INP ENT BAND P.AMP ATT M-CH/RIT SET Appears ■ Memory scan operation (Memory mode) Memory scan searches through memory channel 1 to 199 for signals. Blank (unprogrammed) memory channels are skipped. q P ush V/M to select memory mode. w Close the squelch with the [RF/SQL] control. e Push SCAN to start the scan. • " " appears while scanning. r When the scan detects a signal, the scan stops or pauses depending on the resume setting. t To cancel the scan push SCAN . • Rotating [DIAL] during scan also cancels scan operation. NOTE: Two or more memory channels must be programmed for memory scan to start. MODE TS TUNER FILTER SPCH [RF/SQL] NB NR ANF METER V/M 1 1.8 A=/B 2 3.5 SPLIT 3 7 MW 4 10 M-CL 5 14 AGC 6 18 COMP271 . RIT GENE SCAN 8 24 MNF 0 50 VOX 9 28 F-INP ENT BAND P.AMP ATT M-CH/RIT SET Appears 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 66

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

66
8
SCAN OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Programmed scan operation (VFO mode)
Programmed scan searches for signals between
scan edge memory channels P1 and P2.
The default frequencies for these memories are
0.500000 MHz and 29.99999 MHz, respectively.
See p. 62 for scan edges programming.
q
Push
V/M
to select VFO mode.
w
Push
MODE
to select the desired operating
mode.
• The operating mode can be changed while scanning.
e
Push
TS
to select a tuning step.
• The tuning step cannot be changed while scanning.
(The programmed tuning function can be turned ON
or OFF while scanning.)
r
Set the
[RF/SQL]
control open or closed.
• See the left page for squelch condition.
t
Push
SCAN
to start the scan.
• “
” appears while scanning.
y
When the scan detects a signal, the scan turns
OFF, pauses or ignores it depending on the
resume setting and the squelch condition.
u
To cancel the scan, push
SCAN
.
NOTE:
If the same frequencies are programmed
into both scan edge memory channels P1 and P2,
programmed scan does not start.
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P
.
AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[RF/SQL]
Appears
Memory scan operation (Memory mode)
Memory scan searches through memory channel
1 to 199 for signals. Blank (unprogrammed) memory
channels are skipped.
q
Push
V/M
to select memory mode.
w
Close the squelch with the
[RF/SQL]
control.
e
Push
SCAN
to start the scan.
• “
” appears while scanning.
r
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
t
To cancel the scan push
SCAN
.
• Rotating
[DIAL]
during scan also cancels scan
operation.
NOTE:
Two or more memory channels must be
programmed for memory scan to start.
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P
.
AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[RF/SQL]
Appears