Icom IC-7200 Instruction Manual - Page 48

■ Data mode (SSTV/PSK31) operation

Page 48 highlights

4 RECEIVE AND TRANSMIT ■ Data mode (SSTV/PSK31) operation When operating SSTV or PSK31 with your PC software, consult the manual that is supplied with the software. q Connect a PC to the transceiver. (p. 20) w P ush and hold F-INP ENT BAND for 1 sec., then push a band key to select the desired band. e P ush MODE to select SSB or AM mode. • After SSB mode is selected, push and hold MODE for 1 sec. to toggle between USB and LSB modes. r T urn data mode ON in the quick set mode. q P ush and hold M-CH/RIT SET for 1 sec. to enter the quick set mode. w R otate [M-CH] to select "DATA" to set the data mode. e R otate [DIAL] to select the data mode ON or OFF. • " " appears when the data mode is turned ON. r P ush M-CH/RIT SET to exit the quick set mode and return to normal operation. t R otate [DIAL] to tune in a desired signal and decoded correctly. • The S-meter indicates received signal strength when a signal is received. • Also use the tuning indicator of the software. • During SSB data mode, ¼ tuning function can be used for critical tuning. y Use the PC (software) to transmit. • When operating in SSB data mode, adjust the AF output level from PC so that the ALC meter reading doesn't go outside the ALC zone. NOTE: When the data mode is selected, the audio input from the [ACC] connector* is used for transmission instead of [MIC] connector. The speech compressor function is turned OFF for the SSB data mode transmission. * The desired connector can be selected in the set mode. (p. 77) Band keys MODE TS TUNER FILTER SPCH [DIAL] NB NR ANF METER V/M 1 1.8 A=/B 2 3.5 SPLIT 3 7 MW 4 10 M-CL 5 14 AGC 6 18 COMP271 . RIT GENE SCAN 8 24 MNF 0 50 VOX 9 28 F-INP ENT BAND P.AMP ATT M-CH/RIT SET [M-CH] F-INP ENT BAND Data mode: ON (default: OFF) Either "USB" or "LSB" appears. Appears while transmitting. Appears ✔ For your information Carrier point frequency is displayed when SSB data mode is selected. See the diagram below for the tone-pair example. • Example- LSB/LSB data mode Mark freq.: 2125 Hz Shift freq.: 200 Hz 2325 Hz 200 Hz 2125 Hz Carrier (Displayed frequency) 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

43
4
RECEIVE AND TRANSMIT
Data mode (SSTV/PSK31) operation
When operating SSTV or PSK31 with your PC soft-
ware, consult the manual that is supplied with the
software.
q
Connect a PC to the transceiver. (p. 20)
w
Push and hold
F-INP ENT
BAND
for 1 sec., then push a
band key to select the desired band.
e
Push
MODE
to select SSB or AM mode.
• After SSB mode is selected, push and hold
MODE
for
1 sec. to toggle between USB and LSB modes.
r
Turn data mode ON in the quick set mode.
q
Push and hold
M-CH/RIT
SET
for 1 sec. to enter the
quick set mode.
w
Rotate
[M-CH]
to select “
DATA
” to set the data
mode.
e
Rotate
[DIAL]
to select the data mode ON or
OFF.
• “
” appears when the data mode is turned ON.
r
Push
M-CH/RIT
SET
to exit the quick set mode and
return to normal operation.
t
Rotate
[DIAL]
to tune in a desired signal and de-
coded correctly.
• The S-meter indicates received signal strength when
a signal is received.
• Also use the tuning indicator of the software.
• During SSB data mode, ¼ tuning function can be
used for critical tuning.
y
Use the PC (software) to transmit.
• When operating in SSB data mode, adjust the AF
output level from PC so that the ALC meter reading
doesn’t go outside the ALC zone.
NOTE:
When the data mode is selected, the
audio input from the
[ACC]
connector* is used for
transmission instead of
[MIC]
connector.
The speech compressor function is turned OFF
for the SSB data mode transmission.
* The desired connector can be selected in the set
mode. (p. 77)
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P
.
AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[DIAL]
[M-CH]
Data mode: ON (default: OFF)
F-INP ENT
BAND
Band keys
Either “
USB
” or “
LSB
” appears.
Appears while transmitting.
Appears
4
For your information
Carrier point frequency is displayed when SSB data
mode is selected.
See the diagram below for the tone-pair example.
• Example—
LSB/LSB data mode
Mark freq.: 2125 Hz
Shift freq.: 200 Hz
2325 Hz
200 Hz
2125 Hz
Carrier