Icom IC-7200 Instruction Manual - Page 22
■ Linear amplifier connections, RWARNING - remote control
View all Icom IC-7200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
2 INSTALLATION AND CONNECTIONS ■ Linear amplifier connections CONNECTING THE IC-PW1/EURO To an antenna [ACC-1] Remote control cable (supplied with the IC-PW1/EURO) ACC cable (supplied with the IC-PW1/EURO) 7-pin side [ANT] [REMOTE] EXCITER 1 1&2 OPC-599 conversion cable [ACC] [INPUT1] [GND] [REMOTE] [GND] Transceiver Coaxial cable (supplied with the IC-PW1/EURO) [ANT] IC-PW1/EURO To AC outlet ( ) Non-European versions : 100-120/220-240 V European version : 230 V Ground CONNECTING A NON-ICOM LINEAR AMPLIFIER R WARNING: • Set the transceiver output power and linear amplifier ALC output level by referring to the linear amplifier instruction manual. Be sure the linear amplifier keying circuit control voltage is compatible with the IC-7200, before connecting to the [SEND] connector. • The ALC input level must be in the range +0 V to -4 V, and the transceiver does not accept positive voltage. Non-matched ALC and RF power settings could cause a fire or damage the linear amplifier. To an antenna RF OUTPUT RF INPUT SEND ALC The IC-7200 SEND line is rated at 16 V/200 mA DC. If this level is exceeded, a larger external relay must be used. 50 ø coaxial cable Transceiver [ANT] Non-Icom linear amplifier [SEND] [ALC] 17