Icom IC-7200 Instruction Manual - Page 53
◇ Filter passband width setting, ◇ IF filter shape (SSB/CW only), M-CH], DIAL], TWIN PBT], SHAPE
View all Icom IC-7200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
5 FUNCTIONS FOR RECEIVE D Filter passband width setting q P ush MODE several times to select the desired mode. w P ush and hold FILTER for 1 sec. to enter filter set mode. e Rotate [M-CH] to select "FIL." r P ush FILTER several times to select the desired IF filter. t Rotate [DIAL] to set the desired passband width. • The passband width can be set within the range as shown in the table at right below. • Push and hold M-CL for 1 sec. to return to the default value. y Repeat steps r and t if desired. u P ush and hold FILTER for 1 sec. to exit the filter set mode. When the IF passband width is set to minimum by the [TWIN PBT] controls (when one control is max. counterclockwise, and the other one is max. clockwise; p. 46), a sound may not come from the speaker depending on the IF filter passband width setting. This is not a transceiver's malfunction. MODE TS TUNER FILTER SPCH NB NR ANF METER V/M 1 1.8 A=/B 2 3.5 SPLIT 3 7 MW 4 10 M-CL 5 14 AGC 6 18 COMP271 RIT . GENE SCAN 8 24 MNF 0 50 VOX 9 28 F-INP ENT BAND P.AMP ATT M-CH/RIT SET [DIAL] [M-CH] Mode Filter Wide SSB Middle Narrow Wide SSB Data/ Middle CW Narrow Wide RTTY Middle Narrow AM/ AM Data Wide Middle Narrow Default 3000 Hz 2400 Hz 1800 Hz 1200 Hz 500 Hz 250 Hz 2400 Hz 500 Hz 250 Hz 8000 Hz 6000 Hz 3000 Hz Range (Steps) 50-500 Hz (50 Hz)/ 600-3600 Hz (100 Hz) 50-500 Hz (50 Hz)/ 600-3600 Hz (100 Hz) 50-500 Hz (50 Hz)/ 600-2700 Hz (100 Hz) 200-8000 Hz (200 Hz) D IF filter shape (SSB/CW only) The type of DSP filter shape for SSB and CW can be selected independently from soft and sharp. q P ush MODE several times to select SSB or CW mode. w P ush and hold FILTER for 1 sec. to enter filter set mode. e Rotate [M-CH] to select "SHAPE." r P ush FILTER several times to select the desired IF filter from Wide, Middle or Narrow. t R otate [DIAL] to select the desired filter shape, either soft or sharp • Push and hold M-CL for 1 sec. to return to the default value. y P ush and hold FILTER for 1 sec. to exit the filter set mode. MODE TS TUNER FILTER SPCH NB NR ANF METER V/M 1 1.8 A=/B 2 3.5 SPLIT 3 7 MW 4 10 M-CL 5 14 AGC 6 18 COMP271 RIT . GENE SCAN 8 24 MNF 0 50 VOX 9 28 F-INP ENT BAND P.AMP ATT M-CH/RIT SET [DIAL] [M-CH] "Sharp" "Soft" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 48