Icom IC-7200 Instruction Manual - Page 44

■ Operating RTTY (FSK), ◇ Convenient functions for receive

Page 44 highlights

4 RECEIVE AND TRANSMIT ■ Operating RTTY (FSK) When using your RTTY terminal or TNC, consult the manual that comes with the RTTY terminal or TNC. q P ush and hold F-INP ENT BAND for 1 sec., then push a band key to select the desired band. w P ush MODE to select RTTY mode. • After RTTY mode is selected, push and hold MODE for 1 sec. to toggle between RTTY and RTTY-R modes. e Rotate [DIAL] to tune in a desired signal. • The S-meter indicates received signal strength when signal is received. • If the received signal cannot be demodulated, try se- lecting RTTY-R mode (or RTTY mode). r Transmit a SEND signal from your TNC. • " " appears. • The PO meter indicates the transmitted RTTY signal strength. t Use the connected PC or TNC (TU) to transmit RTTY (FSK) signals. Band keys MODE TS TUNER FILTER SPCH NB NR ANF METER V/M 1 1.8 A=/B 2 3.5 SPLIT 3 7 MW 4 10 M-CL 5 14 AGC 6 18 COMP271 RIT . GENE SCAN 8 24 MNF 0 50 VOX 9 28 F-INP ENT BAND P.AMP ATT M-CH/RIT SET [DIAL] F-INP ENT BAND Appears while transmitting. "RTTY" or "RTTY-R" appears. D Convenient functions for receive • Preamp and attenuator (p. 45) ➥ Push P.AMP ATT to turn the preamp ON or OFF. • " " appears when the preamp is set to ON. ➥ Push and hold P.AMP ATT for 1 sec. to turn the attenu- ator ON. • Push P.AMP ATT to turn the attenuator OFF. • " " appears when the attenuator is set to ON. • Twin PBT (passband tuning) (p. 46) ➥ Rotate [TWIN PBT] (controls-inner/outer). • AGC (auto gain control) (p. 45) ➥ Push AGC once or twice to select the time constant for the AGC circuit fast and slow. • "F.AGC" appears when the fast time constant is selected, and no indicator appears when the slow time constant is selected, respectively. ➥ Push and hold AGC for 1 sec. to turn the AGC function OFF. • "AGC-OFF" appears on the display. • Noise blanker (p. 49) ➥ Push NB to turn the noise blanker ON or OFF. • " " appears when the noise blanker is set to ON. ➥ Push and hold NB for 1 sec. to enter the noise blanker set mode, then rotate [DIAL] to adjust the threshold level, or the blank time. • Rotate [M-CH] to select an item. • Noise reduction (p. 50) ➥ Push NR to turn the noise reduction ON or OFF. • " " appears when the noise reduction is ON. ➥ Push and hold NR for 1 sec. to enter the noise reduction level set mode, then rotate [DIAL] to adjust the noise reduction level. • Manual notch filter (pgs. 51, 52) ➥ Push MNF to turn the manual notch filter ON or OFF. • " " appears when the manual notch filter is set to ON. ➥ Push and hold MNF for 1 sec. to enter the man- ual notch filter set mode, then rotate [DIAL] to select the filter width from narrow, middle and wide. • ¼ function (p. 79) q P ush and hold M-CH/RIT SET for 1 sec. twice to enter the set mode. w R otate [M-CH] to select "DIAL ¼". e R otate [DIAL] to turn the 1⁄4 function ON or OFF. r P ush M-CH/RIT SET to exit the set mode and return to normal operation. 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

39
4
RECEIVE AND TRANSMIT
Operating RTTY (FSK)
When using your RTTY terminal or TNC, consult the
manual that comes with the RTTY terminal or TNC.
q
Push and hold
F-INP ENT
BAND
for 1 sec., then push a
band key to select the desired band.
w
Push
MODE
to select RTTY mode.
• After RTTY mode is selected, push and hold
MODE
for
1 sec. to toggle between RTTY and RTTY-R modes.
e
Rotate
[DIAL]
to tune in a desired signal.
• The S-meter indicates received signal strength when
signal is received.
• If the received signal cannot be demodulated, try se-
lecting RTTY-R mode (or RTTY mode).
r
Transmit a SEND signal from your TNC.
• “
” appears.
• The PO meter indicates the transmitted RTTY signal
strength.
t
Use the connected PC or TNC (TU) to transmit
RTTY (FSK) signals.
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P
.
AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
Band keys
[DIAL]
RTTY
” or “
RTTY-R
” appears.
F-INP ENT
BAND
Appears while transmitting.
D
Convenient functions for receive
• Preamp and attenuator
(p. 45)
Push
P.AMP
ATT
to turn the preamp ON or OFF.
• “
” appears when the preamp is set to ON.
Push and hold
P.AMP
ATT
for 1 sec. to turn the attenu-
ator ON.
• Push
P.AMP
ATT
to turn the attenuator OFF.
• “
” appears when the attenuator is set to ON.
• Twin PBT (passband tuning)
(p. 46)
Rotate
[TWIN PBT]
(controls–inner/outer).
• AGC (auto gain control)
(p. 45)
Push
AGC
once or twice to select the time con-
stant for the AGC circuit fast and slow.
• “
F.AGC
” appears when the fast time constant is se-
lected, and no indicator appears when the slow time
constant is selected, respectively.
Push and hold
AGC
for 1 sec. to turn the AGC
function OFF.
• “
AGC-OFF
” appears on the display.
• Noise blanker
(p. 49)
Push
NB
to turn the noise blanker ON or OFF.
• “
” appears when the noise blanker is set to ON.
Push and hold
NB
for 1 sec. to enter the noise
blanker set mode, then rotate
[DIAL]
to adjust the
threshold level, or the blank time.
• Rotate
[M-CH]
to select an item.
• Noise reduction
(p. 50)
Push
NR
to turn the noise reduction ON or OFF.
• “
” appears when the noise reduction is ON.
Push and hold
NR
for 1 sec. to enter the noise
reduction level set mode, then rotate
[DIAL]
to
adjust the noise reduction level.
• Manual notch filter
(pgs. 51, 52)
Push
MNF
to turn the manual notch filter ON or
OFF.
appears when the manual notch filter is set to
ON.
Push and hold
MNF
for 1 sec. to enter the man-
ual notch filter set mode, then rotate
[DIAL]
to se-
lect the filter width from narrow, middle and wide.
• ¼ function
(p. 79)
q
Push and hold
M-CH/RIT
SET
for 1 sec. twice to enter
the set mode.
w
Rotate
[M-CH]
to select “
DIAL ¼
”.
e
Rotate
[DIAL]
to turn the
1
4
function ON or OFF.
r
Push
M-CH/RIT
SET
to exit the set mode and return to
normal operation.