Icom IC-7200 Instruction Manual - Page 85
Break-In, Break-In Delay, Dot/Dash Ratio, Paddle Polarity, SE Semi : Semi break-in operation.
View all Icom IC-7200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
Break-In This item selects break-in type for CW operation. Full break-in (QSK) activates the receiver between transmitted dots and dashes. This is useful when operating contests, when "fast responses" are common. Semi break-in keeps the receiver quiet between dots and dashes and automatically returns to receive after a preset time from when you stop keying. When break-in is turned off, the key or paddle can generate side tones (selectable in quick set mode) but will not transmit. oF : No break-in operation. SE (Semi) : Semi break-in operation. FL (Full) : Full break-in operation. Break-In Delay This item adjusts break-in delay time for CW semi break-in operation. The delay time is selectable from 0.2 to 13.0 (dots) in 0.1 (dots) steps. Dot/Dash Ratio This item sets the internal electronic keyer dot/dash ratio. 1:1:2.8 to 1:1:4.5 (in 0.1 steps) can be selected. Keying weight example: Morse code "K" DOT (Fixed*) Weight setting: DASH DASH 1:1:3 (default) Weight setting: Adjusted Adjustable range SPACE (Fixed*) *SPACE and DOT length can be adjusted with "Key speed" only in the quick set mode. Paddle Polarity This item sets the paddle polarity. n (Normal) : Normal polarity. r (Reverse) : Reverse polarity. SET MODE 10 OFF (default) 7.5 dots (default) 1:1:3.0 (default) Normal (default) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 80