Icom IC-7200 Instruction Manual - Page 66

MEMORY OPERATION, ■ Memory channels, ■ Memory channel selection

Page 66 highlights

7 MEMORY OPERATION ■ Memory channels The transceiver has 201 memory channels including 2 scan edge channels. Memory mode is very useful for quickly changing to often-used frequencies. All 201 memory channels are tuneable which means the programmed frequency can be tuned temporarily with [DIAL], etc., in memory mode. MEMORY CHANNEL Regular memory channels Scan edge memory channels MEMORY CHANNEL NUMBER 1-199 P1, P2 CAPABILITY Independent transmit and receive frequencies and mode in each memory channel. One frequency and one mode in each memory channel as scan edges for programmed scan. COPY TO VFO Yes Yes OVER­ WRITING CLEAR Yes Yes Yes No ■ Memory channel selection ➔ q Push V/M to select memory mode. • " " appears. w R otate [M-CH] to select the desired memory channel. • If the RIT control indicator lights orange, push M-CH/RIT SET to set the [M-CH] control to memory chan- nel control. (See below for details) • All memory channels including blank channels can be selected. • [UP]/[DN] on the microphone also selects the mem- ory channels. (The only programmed memory chan- nels are selectable.) RIT control indicator goes out Channel increases MODE TS TUNER FILTER SPCH RIT control indicator NB NR ANF METER V/M 1 1.8 A=/B 2 3.5 SPLIT 3 7 MW 4 10 M-CL 5 14 AGC 6 18 COMP271 . RIT GENE SCAN 8 24 MNF 0 50 VOX 9 28 F-INP ENT BAND P.AMP ATT M-CH/RIT SET [M-CH] [EXAMPLE]: Selecting memory channel 17. VFO mode Channel decreases About the [M-CH] control: When the RIT control indicator lights orange, the memory channels cannot be selected with rotat- ing the [M-CH] control because the [M-CH] con- trol acts as the RIT control. So, push M-CH/RIT SET to set the [M-CH] control to memory channel control (RIT control indicator goes out). Memory mode Push Appears Rotate [M-CH] Channel 17 is selected. 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

7
61
MEMORY OPERATION
Memory channels
The transceiver has 201 memory channels including
2 scan edge channels.
Memory mode is very useful for quickly changing to
often-used frequencies.
All 201 memory channels are tuneable which means
the programmed frequency can be tuned temporarily
with
[DIAL]
, etc., in memory mode.
MEMORY
CHANNEL
MEMORY
CHANNEL
NUMBER
CAPABILITY
COPY
TO VFO
OVER-
WRITING
CLEAR
Regular memory
channels
1–199
Independent transmit and receive frequencies
and mode in each memory channel.
Yes
Yes
Yes
Scan edge
memory channels
P1, P2
One frequency and one mode in each memory
channel as scan edges for programmed scan.
Yes
Yes
No
Memory channel selection
q
Push
V/M
to select memory mode.
• “
” appears.
w
Rotate
[M-CH]
to select the desired memory
channel.
• If the RIT control indicator lights orange, push
M-CH/RIT
SET
to set the
[M-CH]
control to memory chan-
nel control. (See below for details)
• All memory channels including blank channels can be
selected.
[UP]
/
[DN]
on the microphone also selects the mem-
ory channels. (The only programmed memory chan-
nels are selectable.)
Channel decreases
Channel increases
RIT control indicator
goes out
About the [M-CH] control:
When the RIT control indicator lights orange, the
memory channels cannot be selected with rotat-
ing the
[M-CH]
control because the
[M-CH]
con-
trol acts as the RIT control. So, push
M-CH/RIT
SET
to
set the
[M-CH]
control to memory channel control
(RIT control indicator goes out).
MODE
TUNER
TS
FILTER
SPCH
V/M
A/B
SPLIT
M-CL
SCAN
SET
ATT
P
.
AMP
COMP
VOX
MNF
RIT
1
2
3
4
5
6
7
8
0
50
28
18
14
10
21
24
=
7
3.5
1.8
F-INP
M-CH/RIT
ENT
BAND
GENE
9
.
AGC
MW
ANF
METER
NR
NB
[M-CH]
RIT control
indicator
[EXAMPLE]:
Selecting memory channel 17.
Push
Appears
Rotate
[M-CH]
VFO mode
Memory mode
Channel 17 is selected.