  • Icom IP100H | Instruction Manual ver. 2.30 - Page 1
    INSTRUCTION MANUAL IP ADVANCED RADIO SYSTEM CONTROLLER IP1000C INTRODUCTION 1 BEFORE USING THE IP1000C 2 SETTING UP THE IP1000C SYSTEM 3 OTHER BASIC FUNCTIONS 4 ABOUT THE SETTING SCREEN 5 MAINTENANCE 6 FOR YOUR INFORMATION
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 2
    design are subject to change without notice or obligation. Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries. Microsoft and Windows
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 3
    of up to 50 ID list and 10 messages can be programmed for each setting group. ••Status settings can be programmed to send the status information (Example: Away from the desk) from the IP100H. - Up to 10 statuses can be programmed. ••The settings configured with the IP1000C is automatically set when
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 4
    is designed for optimal performance when used with an Icom transceiver. Icom is not responsible for the destruction or damage to an Icom device in the event the Icom device is used with equipment that is not manufactured or approved by Icom. NETWORK AND SYSTEM DEFAULT SETTINGS Menu Item Setting
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 5
    Step.1 Step.2 Step.3 Step.4 Step.5 Step.6 Step.7 Connect to a PC and turn ON the power CONNECTION GUIDE ▼ Access the setting screen CONNECTION GUIDE/Section 2 ▼ Configuring the network connection pp. 4-11, 4-12 ▼ Registering the terminals pp. 2-5, 2-6 ▼ Configuring the settings for
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 6
    BEFORE USING THE IP1000C 1 Section 1. Panel description...1-2 MMFront panel...1-2 MMRear panel...1-4 2. Feature description...1-5 MMAbout the basic connection 1-5 MMConnecting transceivers...1-6 MMConnecting a telephone and transceivers 1-6 MMSimplex and Full-Duplex...1-7 MMMulti communication
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 7
    Panel description ■■Front panel 1 234 5 67 1 [UPDATE] button When [MSG] lights green, a firmware update is ready. To download and install the new firmware, hold down this button until [MSG] blinks. •• To use the Firmware Update function, an internet connection, DNS and default gateway settings
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 8
    then securely insert the USB flash drive into the [USB] port. LLIcom is not responsible for all the devices used with the USB flash drive. importing setting data from the USB flash drive to the IP1000C, the originally programmed setting data is automatically saved as "bakdata.sav" on the USB flash
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 9
    1 BEFORE USING THE IP1000C 1. Panel description ■■Rear panel 1 1 [CONSOLE] port (RJ-11 type 2 [LAN] ports (RJ-45 type×4 2 3 45 Connect an RS-232C serial communication interface to externally configure the IP1000C. (Optional OPC-1402A is required.) Connect the network devices such as a HUB.
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 10
    . CS-IP100H (Cloning software) The CS-IP100H cloning software is designed to be used for data entry, setting and programming for the IP100H from a PC. (You can download the free software from the Icom's website) ••Connect the cloning cables correctly according to the CS-IP100H instruction manual
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 11
    ] [D-TRX1] P0 P1 P2 P3 P4 Wireless access point CT-24 IP100H LLOnly the VE-PG3's controller ports that are set as the bridge mode Repeater Transceiver ■■Connecting a telephone and transceivers If you connect in bridge connection with Icom's VE-PG3 (ver. 1.13 or later), you will be able to
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 12
    and Full-Duplex IP1000C Simplex Wireless access point Full-Duplex IP100H HM-153 HM-153LS HM-166 HM-166LS HM-183LS HM headset OPC-2006LS headset OPC-2006LS throat microphone OPC-2006LS headset OPC-2359*3 ✓ ✓ ✓ ✓ ✓ ✓ Enable Enable Enable Enable *1 When a headset that supports the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 13
    Calls The Group Call function is used to call the desired group selected from the ID List. ••It is required to divide the registered IP100H and IP100FS in the [Transceiver Registration] screen into groups in the [Destination Settings] screen. ••The ID List and the destination settings set in the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 14
    [Destination Settings] screen and [ID List] screen. If the "Talkgroup Type" in the [Destination Settings] screen is set to "Multiplex Talkgroup," the IP100H can make a Talkgroup Call between the linked talkgroups. ••Set to the IP1000C whether All Call includes the Talkgroup or not, or the Talkgroup
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 15
    to notify a Call is received. IP1000C Individual Call Wireless access point IP100H Sales 1 Sales 8 10/8 16:57 Sales 8 Selecting an Individual Call seconds) About blocking the communications while in the TalkBack Timer If there are new calls while in the TalkBack Timer, it is set to receive the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 16
    . Change the target during communication with the Priority Call function enabled IP1000C Wireless access point Group Call Making an Individual Call during communication Group Call IP100H Individual Call 1-11
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 17
    [Area Call] screen in the [RoIP Server Settings] menu. (Example: For Sales and For Accounts) When the IP100FS uses the Area Call function, can call IP100Hs that are in the communication range of the access points assigned to the Area Call. Select the access point in the [Location], the Call type
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 18
    in the [Messages] screen of the [Common Setting] Menu. Up to 10 messages can be registered. IP100H transmits a message IP1000C Message All Gather immedi Message selection screen (TX) IP100H Wireless access point All Call Blinks Scrolls 1/25 12:57 All Gather imme Received messege screen (RX
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 19
    description ■■About Status Settings Set the Status to send the status information (Example: Away from the desk) from the IP100H.  (Default: Disable) ••The status information of up to 32 characters can be programmed in the [Status] screen on the [Common Settings] menu. Up to 10 status can be
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 20
    the Setting procedures 2-3 2. Transceiver settings...2-4 MMRegistering the terminals...2-5 MMAbout confirming the registration and rebooting the IP100H 2-6 MMAbout the IP100H settings...2-7 MMAbout the Group calls...2-8 MMAbout the Talkgroup calls...2-9 MMAbout the ID list...2-11 MMAbout messages
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 21
    SETTING UP THE IP1000C SYSTEM 1. Flow using IP100H ■■Prepare for connection and settings This is an explanation of the flow from connecting with PC to accessing to the Setting screen. 1. Connect to a PC and turn ON the power See the CONNECTION GUIDE (Separated) for details Connect a PC to the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 22
    or external), provisioning server setting (IP1000C) to all the IP100Hs. ••The CS-IP100H is a freeware that can be downloaded from the Icom website. ••First, read the instructions of the CS-IP100H that can be downloaded from the Icom website, and follow its procedure to connect the cloning cable
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 23
    to connect an optional headset and connection cable. Headset HS-94, HS-95, or HS-97 and Connection cable OPC-2006LS. Or Headset HS-102 and Connection versions, up to 20 of total IP100H and IP100FS can be registered.) ••This manual explains that IP addresses of the IP100H or a PC using the IP100FS
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 24
    UP THE IP1000C SYSTEM 2. Transceiver settings ■■Registering the terminals Set the Unit ID (Individual number) to register each IP100H or IP100FS. 1 Click [Transceiver Settings], then [Transceiver Registration]. ••The [Transceiver Registration] screen is displayed. 2 Enter the "Transceiver
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 25
    the IP1000C is completed, program the IP100H using the CS-IP100H cloning software and a PC. After that, reboot the IP100H and it will automatically read the contents of the IP1000C's setting. ••The CS-IP100H is a freeware that can be downloaded from the Icom website. ••If the IP100H will not display
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 26
    2 SETTING UP THE IP1000C SYSTEM 2. Transceiver settings ■■About the IP100H settings Set and assign functions to each registered IP100H. After the settings have been changed, the IP100H needs to be rebooted. 1 Click [Transceiver Settings], then [Transceiver Settings]. ••The [Transceiver Settings]
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 27
    , and they communicate with the full-duplex operation between three or more members as meeting. After the settings have been changed, the IP100H needs to be rebooted. 1 Click [Destination Settings]. ••The [Destination Settings] screen is displayed. 2 Enter the group name, Call type, and Group ID
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 28
    the IP1000C. The [FUNC] key or [ID List] key can be assigned for selecting the Talkgroup. After the settings have been changed, the IP100H needs to be rebooted. 1 Click [Destination Settings]. ••The [Destination Settings] screen is displayed. 2 Enter the Talkgroup name, Call type, and Group ID
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 29
    , and so on. 2. Push [r] or [s] (w) to select the Talkgroup number. Talkgroup 00202 Talkgroup 2 w q e 3. Push [CLR/LOCK] (e). ••You can talk with the IP100Hs or IP100FSs that select the same group number. (Example 00202) ••When you select the Talkgroup Call, you 10/3 12:57 Talkgroup 2 are
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 30
    THE IP1000C SYSTEM 2. Transceiver settings ■■About the ID list Enter Names, Call types and so on in an ID list that the IP100H will use. After registration is finished, the IP100H needs to be rebooted. When using the ID list, set the "Use ID List" to "Enable." (p.4-40) 1 Click [Common Settings
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 31
    2 SETTING UP THE IP1000C SYSTEM 2. Transceiver settings ■■About messages Enter messages that the IP100H will transmit. After registration is finished, the IP100H needs to be rebooted. When using the Message, set the "Message" to "Enable." (p.4-45) 1 Click [Common Settings], then [Messages]. ••
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 32
    2 SETTING UP THE IP1000C SYSTEM 2. Transceiver settings ■■About the status settings Enter the status that the IP100H will transmit. After registration is finished, the IP100H needs to be rebooted. When using the Status, set the "Status" to "Enable." (p.4-46) 1 Click [Common Settings], then [
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 33
    number in the "Profile" field. ••The profile number setting (example: 1) is specified in the "Profile" item on the [Transceiver Registration] screen in each IP100H. 3 Select the "ID List" and "Message List" in the "Profile" field. Enter Select the specified ID list group on the [ID List] screen
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 34
    connecting the VE-PG3, check the firmware version on the VE-PG3's setting screen. Bridge connection Extension number 2001 IP1000C 192.168.0.1 IP100H Sales1 00001 Seles group1 00011 Wireless access point Sales2 00002 VE-PG3 (RoIP Gateway) 192.168.0.2 IP phone Extension number 500 About the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 35
    2 SETTING UP THE IP1000C SYSTEM 3. Bridge connection and Caller settings Bridge connection Extension number 2001 IP1000C 192.168.0.1 IP100H Sales1 00001 Seles group1 00011 Wireless access point Sales2 00002 VE-PG3 (RoIP Gateway) 192.168.0.2 IP phone Extension number 500 About the IP1000C
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 36
    2 SETTING UP THE IP1000C SYSTEM 3. Bridge connection and Caller settings Bridge connection Extension number 2001 IP1000C 192.168.0.1 IP100H Sales1 00001 Seles group1 00011 Wireless access point Sales2 00002 VE-PG3 (RoIP Gateway) 192.168.0.2 IP phone Extension number 500 About the VE-PG3
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 37
    ) See the VE-PG3 instruction manual for the setting details. When the IP100H (example: Sales 2 "00002") calls the IP phone: 1. Display the IP phone's Destination phone number on the IP100H's screen. ••The Destination phone number of the IP phone must be programmed in the IP100H's ID list. 2. Hold
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 38
    another sites. LLUp to 10 sub IP1000Cs can be connected to a master IP1000C. LLUse a VPN router, such as Icom's SR-VPN1, between sites if necessary. IP100H makes a Group Call with the Additional Controller Link IP1000C 192.168.0.1 Office1 (Master) Wireless access point Additional Controller Link
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 39
    192.168.0.1 Office1 (Master) Additional Controller Link Wireless access point Sales1 00001 Sales group1 00101 Sales2 00002 192.168.0.2 Office2 (Sub) IP100H Sales21 00021 Sales group2 00201 Sales22 00022 192.168.0.3 Office3 (Sub) Sales31 00031 Sales group3 00301 Sales32 00032 About the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 40
    192.168.0.1 Office1 (Master) Additional Controller Link Wireless access point Sales1 00001 Sales group1 00101 Sales2 00002 192.168.0.2 Office2 (Sub) IP100H Sales21 00021 Sales group2 00201 Sales22 00022 192.168.0.3 Office3 (Sub) Sales31 00031 Sales group3 00301 Sales32 00032 About the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 41
    192.168.0.1 Office1 (Master) Additional Controller Link Wireless access point Sales1 00001 Sales group1 00101 Sales2 00002 192.168.0.2 Office2 (Sub) IP100H Sales21 00021 Sales group2 00201 Sales22 00022 192.168.0.3 Office3 (Sub) Sales31 00031 Sales group3 00301 Sales32 00032 About the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 42
    192.168.0.1 Office1 (Master) Additional Controller Link Wireless access point Sales1 00001 Sales group1 00101 Sales2 00002 192.168.0.2 Office2 (Sub) IP100H Sales21 00021 Sales group2 00201 Sales22 00022 192.168.0.3 Office3 (Sub) Sales31 00031 Sales group3 00301 Sales32 00032 About the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 43
    192.168.0.1 Office1 (Master) Additional Controller Link Wireless access point Sales1 00001 Sales group1 00101 Sales2 00002 192.168.0.2 Office2 (Sub) IP100H Sales21 00021 Sales group2 00201 Sales22 00022 192.168.0.3 Office3 (Sub) Sales31 00031 Sales group3 00301 Sales32 00032 About the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 44
    makes a Group Call with the Additional Controller Link (VE-PG3) IP1000C Additional Controller Link Controller connection 192.168.0.2 (Area A) 192.168.0.3 (Area B) IP100H Sales31 00031 VE-PG3 (RoIP Gateway) [USB] [D-TRX1] P0 P1 P2 P3 P4 192.168.0.11 CT-24 Sales group3 00301 Sales32
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 45
    makes a Group Call with the Additional Controller Link (VE-PG3) IP1000C Additional Controller Link Controller connection 192.168.0.2 (Area A) 192.168.0.3 (Area B) IP100H Sales31 00031 VE-PG3 (RoIP Gateway) [USB] [D-TRX1] P0 P1 P2 P3 P4 192.168.0.11 CT-24 Sales group3 00301 Sales32
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 46
    makes a Group Call with the Additional Controller Link (VE-PG3) IP1000C Additional Controller Link Controller connection 192.168.0.2 (Area A) 192.168.0.3 (Area B) IP100H Sales31 00031 VE-PG3 (RoIP Gateway) [USB] [D-TRX1] P0 P1 P2 P3 P4 192.168.0.11 CT-24 Sales group3 00301 Sales32
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 47
    makes a Group Call with the Additional Controller Link (VE-PG3) IP1000C Additional Controller Link Controller connection 192.168.0.2 (Area A) 192.168.0.3 (Area B) IP100H Sales31 00031 VE-PG3 (RoIP Gateway) [USB] [D-TRX1] P0 P1 P2 P3 P4 192.168.0.11 CT-24 Sales group3 00301 Sales32
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 48
    makes a Group Call with the Additional Controller Link (VE-PG3) IP1000C Additional Controller Link Controller connection 192.168.0.2 (Area A) 192.168.0.3 (Area B) IP100H Sales31 00031 VE-PG3 (RoIP Gateway) [USB] [D-TRX1] P0 P1 P2 P3 P4 192.168.0.11 CT-24 Sales group3 00301 Sales32
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 49
    makes a Group Call with the Additional Controller Link (VE-PG3) IP1000C Additional Controller Link Controller connection 192.168.0.2 (Area A) 192.168.0.3 (Area B) IP100H Sales31 00031 VE-PG3 (RoIP Gateway) [USB] [D-TRX1] P0 P1 P2 P3 P4 192.168.0.11 CT-24 Sales group3 00301 Sales32
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 50
    Link Controller connection 192.168.0.2 (Area A) 192.168.0.3 (Area B) IP100H Sales31 00031 VE-PG3 (RoIP Gateway) [USB] [D-TRX1] P0 P1 Example: 192.168.0.3) Enter the Controller Port Number same as the IP1000C' Service port number in the Link setting field. (Example: 32000) Enter the Local
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 51
    OTHER BASIC FUNCTIONS 3 Section 1. How to restrict access...3-2 MMSetting password...3-2 2. How to set the IP1000C's internal clock time 3-3 MMSetting date and time (Manual setting 3-3 MMSetting date and time (Automatic setting 3-3 3. Using the DHCP function...3-4 MMSetting example...3-4 3-1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 52
    BASIC FUNCTIONS 1. How to restrict access If you set a new administrator password, you can restrict access to the IP1000C's setting ••The [Administrator] screen appears. 2 Enter [Current Password], [New Password] and [New Password (confirm)] in their respective input fields. LLThe password can
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 53
    3 OTHER BASIC FUNCTIONS 2. How to set the IP1000C's internal clock time You can set the IP1000C's internal clock time. ■■Setting date and time (Manual setting) 1 Click the [Management] menu, then [Date and Time]. ••The [Date and Time] screen appears. 2 Verify the PC's current time in the [Date
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 54
    Server" item, and then click . Enter the new IP pool start address and so on, depending on your asked to reboot the IP1000C, follow the instructions. e Click Click About the DHCP server address conflict, a network problem will occur. See the Troubleshooting section for possible solutions.
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 55
    ABOUT THE SETTING SCREEN 4 Section 1. About the setting screen...4-4 2. [TOP] Menu 4-5 MMSystem Status...4-5 MMNetwork Status...4-5 MMPort Status...4-6 MMTRX Status...4-6 3. [Information] Menu 4-7 MMSYSLOG...4-7 MMMemory Usage...4-8 MMTraffic Statistics...4-9 4. [Network Settings] Menu 4-10
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 56
    4 ABOUT THE SETTING SCREEN (Continued from the previous page) 7. [RoIP Server Settings] Menu 4-22 MMCall Type Priority...4-22 MMTelephone Gateway Interconnection 4-23 MMTelephone Gateway Interconnection Entry List 4-24 MMTelephone Gateway Interconnection Group 4-25 MMTelephone Gateway
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 57
    4 ABOUT THE SETTING SCREEN (Continued from the previous page) 10. [Destination Settings] Menu 4-94 MMDestination Setting...4-94 MMList of Destination Setting Entries (All Call 4-104 MMList of Destination Setting Entries (Group Call 4-104 MMList of Destination Setting Entries (Talkgroup Call 4-
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 58
    the setting screen Icom website link Setting menu Setting screen Setting buttons Icom website link Click the Icom logo to open the Icom website, if your or cancel setting values. If "A reboot is required to apply all the new settings." is displayed on the screen when you click the [Apply] button,
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 59
    ). ••The MAC address is also printed on the label on the bottom of the IP1000C. ••The version information of the firmware in every IP100H registered into this IP1000C can be checked on the [TRX status] field. (p. 4-6) ■■Network Status Displays the network information such as IP address. (This
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 60
    mode, auto-negotiation enabled devices (including the IP1000C) may generally take it for half-duplex mode and cannot communicate properly. ■■TRX Status Displays the registered IP100Hs' or IP100FSs' information such as the Registration status, IP Address, and Version. (This is only an example.) 4-6
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 61
    4 ABOUT THE SETTING SCREEN 3. [Information] Menu ■■SYSLOG Displays the log information. The latest 500 log entries are displayed. [Information]-[SYSLOG] 1 2 3 (This is only an example.) 1 Severity 2
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 62
    4 ABOUT THE SETTING SCREEN 3. [Information] Menu ■■Memory Usage Displays a statistical graph of the memory usage. LLThese setting items are reset when you leave this screen. [Information]-[Statistics] 1 2 3 1 Plot Interval 2 Automatic Refresh ��� 3
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 63
    4 ABOUT THE SETTING SCREEN 3. [Information] Menu ■■Traffic Statistics Displays the traffic graph for LAN port. LLThese setting items are reset when you leave this screen. [Information]-[Statistics] 1 2 3 1 Plot Interval 2 Automatic Refresh ��� 3
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 64
    4 ABOUT THE SETTING SCREEN 4. [Network Settings] Menu ■■Host Name Enter the host name. [Network Settings]-[IP Address] Host Name Enter the host name. (Up to 31 characters) (Default: IP1000C) LLThe name must start with an alphanumeric character, and must NOT start or end with a "-." 4-10
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 65
    gateway device (such as a router) is connected to the LAN port, enter the device's IP address. Enter the DNS server address specified by your service provider. If you have two DNS server addresses, enter the primary address. Enter the secondary DNS server address, if you have two DNS server
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 66
    size of IP pool. (Default: 128) LLUp to 128 addresses can be automatically assigned by the DHCP server function. Another 32 addresses can be manually assigned. Enter the subnet mask for the IP pool start address set in the "IP Pool Start Address" item (2). (Default: 255.255.255.0) Enter
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 67
    WINS Server �� 11 Secondary WINS Server � 12
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 68
    not overlap or conflict. If a DHCP server is already connected to the network, and there is an address conflict, a network problem will occur. See the Troubleshooting section for possible solutions. ■■Static DHCP Table Displays the static DHCP entries.
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 69
    4 ABOUT THE SETTING SCREEN 4. [Network Settings] Menu ■■Routing Table Displays the routing information. 1 2 3 [Network Settings]-[Static Routing] 4 5 (This is only an example.) 1 Destination 2 Subnet Mask 3 Gateway 4 Interface 5 Owner The network address of the route's destination
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 70
    4 ABOUT THE SETTING SCREEN 4. [Network Settings] Menu ■■Static Routing Enter the static routing destinations. LLYou can enter up to 32 entries. 1 2 3 [Network Settings]-[Static Routing] 4 (This is only an example.) 1 Destination 2 Subnet Mask 3 Gateway 4
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 71
    selecting "Enable," you can communicate with the IP100Hs and the IP100FS registered to additional controllers. LLRegister PG3 must be linked to the IP1000C whose Controller mode is set to "Master." 3 Service Port Number �� Enter the port number for receiving audio signals. Range: "2" to "65534
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 72
    4 ABOUT THE SETTING SCREEN 5. [RoIP Settings] Menu [RoIP Settings]-[VoIP Extension] ■■VoIP Extension Set the V/RoIP details. LLThe items on the [RoIP Settings] screen differ depending on the TOS type setting. TOS Type: Not used 1 2 3 56 TOS Type: TOS 1 2 3 4 56 TOS Type: Diffserv 1 2 3 4
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 73
    TOS Type: Diffserv 1 2 3 4 56 (These are examples when the "Receive Buffer Type" item is set to "Static.") 3 TOS type Select the TOS (Type-Of Service) format. (Default: TOS) ••Not used Does not use the TOS function. •• TOS Sends the VoIP packets to TOS field (8 bits) in the IP header using
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 74
    1 2 3 4 56 TOS Type: Diffserv 1 2 3 4 56 (These are examples when the "Receive Buffer Type" item is set to "Static.") 4 Media (RTP Select the Priority level and Service type of the sent VoIP packets. ••Priority Level Set the TOS priority level between 0 to 7 in decimal. (Default
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 75
    SETTING SCREEN 6. [Tenant (Fleet) Settings] Menu [Tenant (Fleet) Settings]-[Tenant (Fleet)] ■■Tenant (Fleet) The tenant (fleet) divides the IP100Hs or IP100FSs which belong to this IP1000C for a system management purpose. (Example: Security company/Commissioned company) LLThe terminals cannot
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 76
    4 ABOUT THE SETTING SCREEN 7. [RoIP Server Settings] Menu ■■Call Type Priority Select the priority level of the call types. [RoIP Server Settings]-[Call Type Priority] 1 23 (This is only an example.) 1 Call type Priority (High to Low) Select the priority level of the call types.  (Default:
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 77
    the Telephone Gateway Interconnection with a VE-PG3. 1 2 3 4 56 (This is only an example.) 1 No 2 Destination Address ��� 3 Destination Port Number � 4 Service Port Number �� 5
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 78
    4 ABOUT THE SETTING SCREEN 7. [RoIP Server Settings] Menu [RoIP Server Settings]-[Telephone Gateway Interconnection] ■■Telephone Gateway Interconnection Entry List The list of the registered device for the Telephone Gateway Interconnection. 12 3 (This is only an example.) 1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 79
    4 ABOUT THE SETTING SCREEN 7. [RoIP Server Settings] Menu [RoIP Server Settings]-[Telephone Gateway Interconnection] ■■Telephone Gateway Interconnection Group If the courses of the Telephone Gateway Interconnection to the VE-PG3s are made into a group, the unused course in the group can be
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 80
    4 ABOUT THE SETTING SCREEN 7. [RoIP Server Settings] Menu [RoIP Server Settings]-[Telephone Gateway Interconnection] ■■Telephone Gateway Interconnection Group Entry List The list of the registered Telephone Gateway Interconnection group. 12 3 (This is only an example.) 1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 81
    group name. (Up to 31 characters) Enter the destination device's IP address or domain name. (Up to 63 characters) Enter the destination controller's service port number of the Additional Controller Settings (p. 4-17). Range: "2" to "65534" (only even numbers) LLThe set port number (RTP) and the port
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 82
    4 ABOUT THE SETTING SCREEN 7. [RoIP Server Settings] Menu [RoIP Server Settings]-[Additional Controller Link] ■■Linked Controller List The [Linked Controller List] is a list of the destination IP addresses and port numbers registered to this IP1000C. (This is only an example.) 1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 83
    points can be registered to the area. Click to apply the entries. Click to restore the settings. LLYou cannot restore after clicking . The IP100H makes All call in the area Example: The wireless access points "Sales" and "Accounts" are registered in the same area. The access point "Parts
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 84
    4 ABOUT THE SETTING SCREEN 7. [RoIP Server Settings] Menu [RoIP Server Settings]-[Area Call] ■■Access Point Search The IP1000C can search an access point on the network to register the access point for Area Call. LLIcom guarantees this function only for the AP-90M and AP-95M. (As of June 2020)
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 85
    4 ABOUT THE SETTING SCREEN 7. [RoIP Server Settings] Menu ■■Area Entry List The list of the registered Area setting. [RoIP Server Settings]-[Area Call] 12 3 (This is only an example.) 1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 86
    the Status function is set to OFF, "-" is displayed. ••If you click the button (7), the latest status will be displayed. ••When the IP100H is remotely locked by the IP100FS, and it cannot communicate with others or cannot transmit, "Transmit and receive disabled" or "Transmit disabled" is
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 87
    IP1000C. LLWhile the "Registration Status" displays "Disconnected," "-" is displayed. 9 Manual Update Select "Enable" to manually update the IP100H firmware when the IP1000C sends the reboot command (10) to the IP100H. When the IP100H is ready to update the firmware, "F" blinks on the display
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 88
    numbers, symbols can be used. Enter the port number that the IP100H uses to communicate with the IP1000C. (UDP port) LL Informatio •• for the communication. ••We recommend to use default port number, if it is not problem. ••The default number differs, depending on the [TRX No.] as shown below. (
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 89
    Enter the port number that the IP1000C uses to communicate with the IP100H or IP100FS. (UDP port) LL Informatio ••The set port number for the communication. ••We recommend to use default port number, if it is not problem. ••The default number differs, depending on the [TRX No.] as shown below. (
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 90
    4 ABOUT THE SETTING SCREEN 8. [Transceiver Settings] Menu ■■Transceiver Setting Entry List The list of the registered IP100Hs or IP100FSs. [Transceiver Settings]-[Transceiver Registration] 1 2 (This is only an example.) 1 Selection Box 2
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 91
    LLIf a Destination ID is already registered, "Duplicate IDs" is displayed. Select the default settings or the programmed settings to refer to.  (Default: Default) Select a profile number, which IP100Hs or IP100FSs belong to.  (Default: 1) LL1 to 100 are selectable. LLYou can set an ID List
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 92
    . The individual number that the "Transceiver Model" item on the [Transceiver Registration] screen is set to "IP100FS," cannot be selected. Select whether the IP100H displays the Date and Time or its Name in the standby mode. (Default: Date and Time) LLIf the "Name" item on the [Transceiver
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 93
    mode or not. (Default: Enable) •• Enable The Destination ID (Call type) is displayed on the standby mode. LLWhen the PTT on the IP100H is pushed, the IP100H calls the displayed ID (Call type). •• Disable The Destination ID (Call type) is not displayed on the standby mode. LLThe Destination ID (Call
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 94
    "Call Type" item, as below, even if you push the [ ] key on the IP100H. LLIf you set the Call Type to "Individual" or "Group," enter the destination ID . Select whether or not to display All Call in the ID list of the IP100H.  (Default: Disable) •• Disable Does not display "All" in the ID
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 95
    11 Notice Tone and Vibration Select a talkgroup if you want to set the IP100H to join a talkgroup when you turn ON the power. (Default: Disable) Call ID" in the "User ID List" item (7) is displayed when the IP100H is turned ON. •• Enable The IP100 joins the selected talkgroup when it is
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 96
    ] 12 13 14 15 16 17 (This is only an example.) 12 Volume (Except Reception Notice) 13 Communication Method � Set the beep level when the IP100H transmits a Call or connecting to the IP1000C to between 0 and 32. (Default: 10) LLWhen this setting is set to "0," the notification beep becomes OFF
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 97
     ■■Transceiver Settings [Transceiver Settings]-[Transceiver Settings] 12 13 14 15 16 17 (This is only an example.) 14 Priority Call Select whether the IP100H uses the Priority Call or not.  (Default: Disable) The priority levels of the Call types are in the following order. Priority level
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 98
    ] screen in the [RoIP Server Settings] menu. (Example: For Sales and For Accounts) When the IP100FS uses the Area Call function, the IP100FS can call IP100Hs that are in the communication range of the access points assigned to the Area Call. Select the access point in the [Location], the Call type
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 99
    the messages or not.  (Default: Disable) When "Enable" is selected, push [FUNC] on the IP100H once to enter the Message selection screen. LLUp to 10 messages of 32 characters or less can be programmed on the [Messages] screen in the [Common Settings] menu. LLSelect the message number 1 to 10
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 100
    . LLUp to 10 statuses of 32 characters or less can be entered on the [Status] screen in the [Common Settings] menu. LLThe status that the IP100H sends can be displayed on the [Transceiver Management] screen in the [Transceiver Settings] menu or the one-Touch button of the IP100FS. IP100FS One-Touch
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 101
    or not.  (Default: Disable) When this setting is set to "Enable," the IP1000C sends the mixing audio of all calls that call to the IP100H. LLThe IP100H displays the called station that has the highest priority in the mixing audio. See page 4-43 for details of the Priority level. • Mixing of
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 102
    . When the external microphone's PTT switch is held down, or its VOX function is active, the IP100H calls the preset destination. (Example: Group call is specified to the Earphone Mic or Headset) LL Informatio ••Specify the Call type from "Individual," "Group" or "All." ••When the "Call Type" item
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 103
    Transceiver Settings] 20 21 (This is only an example.) 20 Option Key Assign "Message," "One Touch," "Clear down," "Mute," "Emergency," or "No function" to the IP100H's Option key. (Default: No Function) LLWhen this setting is set to "No function," nothing changes by pushing [Option] on the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 104
    Settings [Transceiver Settings]-[Transceiver Settings] 20 21 (This is only an example.) 20 Option key • One Touch Pushing [Option] on the IP100H selects a specified Call type and destination ID or phone number. Specify the "Individual," "Group," "All" or "Telephone" Call type. LLWhen
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 105
    assign another function, if you select "Enable" on the [Clear Down during Telephone Call] (21) item. •• Mute Hold down [Option] for 1 second on the IP100H when you want to mute the received audio. (The Notification beep cannot be muted.) Hold down [Option] for 1 second to turn the mute function
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 106
    SW OFF Timer] item (36). 21 Clear Down during Telephone Call Select "Enable," if you want to terminate the phone call by pushing the IP100H's [Option] key. (Default: Enable) LLWhen "Clear Down" is selected on the [Option Key] item (20), this item is not displayed. Before the target telephone
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 107
    .) 22 Target Availability Check � 23 Key-Touch Beep Select whether the IP100H displays a confirmation after it makes an Individual Call, or not. (Default: Enable) When "Enable" is selected, the IP100H displays the "Connected," "Busy" or "No response" connection status. 1/24
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 108
    Adjust the microphone sensitivity. (Default: 0 (dB)) The adjustable range is -12 (low) to 12 (high) dB, in 3 dB steps. LLWhen the noise level around the IP100H is high, set to low sensitivity and speak in a slightly louder voice that helps listening easily. Or when the noise level around the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 109
    cable OPC-2006LS. Or Headset HS-102 and Connection cable OPC-2359. • The VOX function starts transmission when you speak into the microphone, without needing to push [PTT]; then, automatically returns to reception when you stop speaking. • Be sure to turn OFF the IP100H's power, before connecting or
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 110
    time to between 5 and 2000 milliseconds in 5 milliseconds steps. (Default: 50 (milliseconds)) When audio from a headset microphone is input for this specified time, the IP100H starts transmitting. Adjust the Release time to between 5 and 2000 milliseconds in 5 milliseconds steps. (Default
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 111
    10. (Default: 2 seconds) Select whether or not to sound an alarm when the emergency call is sent. When this item is set to "Disable," IP100H sends the emergency call silently, without any alert on itself. (Default: Enable) When "Enable" is selected, set the Volume (audio level) of the alarm
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 112
    4 ABOUT THE SETTING SCREEN 8. [Transceiver Settings] Menu ■ Transceiver Settings [Transceiver Settings]-[Transceiver Settings] < = 35 36 @ A B D E (This is only an example.) A Call type Emergency: Enable B Cancel on Reply Emergency: Enable D Cancel by Time Emergency: Enable E Alert Tone
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 113
    ) Enter the time period for starting the Lone Worker function within the range of 1 to 255 minutes (1 minute steps). (Default: 60 (minutes)) • When the IP100H is operated within the time period in this item, the times for the "Lone Worker ON Timer" (43) and "Lone Worker Reminder Timer" (44) are
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 114
    but it may frequently break the audio signal. K TOS type • Dynamic The buffer time changes according to the audio fluctuation. Select the TOS (Type-Of Service) format. (Default: TOS) • Not used The TOS function is disabled. • TOS Sends the 8 bit VoIP packets to the TOS field in the IP header
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 115
    8. [Transceiver Settings] Menu ■ Transceiver Settings [Transceiver Settings]-[Transceiver Settings] J K L M O (This is only an example.) L Media (RTP Select the Priority level and Service type of the sent VoIP packets. • Priority Level Set the TOS priority level to between 0 and 7. (Default
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 116
    (This is only an example.) M Selected Antenna Select the Antenna that the IP100H will use. (Default: Transceiver's Setting) • Transceiver's Setting Uses the last antenna set by the CS-IP100H or IP1000C. • Internal Antenna Uses the internal antenna. The internal antenna reduces the communication
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 117
    's IP settings. (Default: Transceiver's Setting) • Transceiver Setting Uses the last IP setting set by the CS-IP100H or IP1000C. • DHCP Client Selects the DHCP Client when the IP address is automatically obtained by a DHCP server. L If necessary, enter the "Primary DNS Server"
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 118
    IP1000C is used as its Provisioning Server, this entry is not necessary. Q Accept reboot command nrom other than the master controller �� Select whether the IP100Hs can be rebooted by the other than the specified Provisioning server nor not. (Default: Disable ) L Only the IP1000C and VE-PG4 is
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 119
    Settings]-[Transceiver Settings] P Q R S T U V W X Z (This is only an example.) S Automatic Firmware Updating at Power ON Select whether the IP100H will use the Automatic Update function or not. (Default: Enable (with Automatic Reboot)) • Disable Disables the automatic firmware updating
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 120
    of up to 16 characters. The password is used when reading from or writing to the IP100H, or updating the firmware using the CS-IP100H*. * CS-IP100H is the cloning sofware for IP100H, and can be downloaded from the Icom website. Click to apply the entries. Click to restore the settings. L You cannot
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 121
    to apply the entries. Click to restore the settings. L You cannot restore after clicking . ■ Transceiver Setting List The list of the registered IP100Hs. L When verifying the contents or editing the settings, select the individual number in Unit ID item. (This is only an example.) 4-67
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 122
    . (Default: M✔ 11g, M✔11a) Selecting "11g" includes "11b." LLAccess points that comply with the wireless LAN standards, can be used with the IP100H. Set the IP100H transmit power level to between High, Middle and Low.  (Default: High) LLWhen "High" is selected, the transmission distance of the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 123
    wireless network group is identified by the SSID (wireless network name). ••If you register two or more SSIDs, the IP100H connects to the SSID which has the strongest radio wave. ••For any other wireless device, this may be called ESSID. ••The setting data before version 2.04 automatically moves
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 124
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu ■■Wireless LAN [Common Settings]-[Wireless LAN] 1 2 3 4 5 6 7 8 9 (This is only an example.) 7 Authentication 10 11 Select the authentication method that is the same as the wireless access point. (Default: Open System/Shared Key)
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 125
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu ■■Wireless LAN [Common Settings]-[Wireless LAN] 1 2 3 4 5 6 7 8 9 (This is only an example.) 8 Encryption 10 11 Select the encryption type that is the same as the wireless access point. (Default: None) LLBe sure to verify the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 126
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu ■■Wireless LAN [Common Settings]-[Wireless LAN] 1 2 3 4 5 6 7 8 9 (This is only an example.) 9 WEP Encryption Key or PSK (Pre-Shared Key) �� 10 11 • WEP Encryption Key Enter the encryption key that is the same as the wireless access
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 127
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu ■■Wireless LAN [Common Settings]-[Wireless LAN] 1 2 3 4 5 6 7 8 9 (This is only an example.) 10
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 128
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu ■■List of Wireless LAN Entries The list of the wireless LAN settings. [Common Settings]-[Wireless LAN] (This is only an example.) 1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 129
    SCREEN 9. [Common Settings] Menu [Common Settings]-[ID List] ■■ID List Common Settings Selects an ID list that the IP100Hs will use. LLYou can individually specify an ID list that the IP100Hs belong to the groups in the "Profile" field on the [Common Settings] screen. LLIf any entries on this
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 130
    the ID List Setting You can save an ID list file on your PC or load an ID list file to the IP1000C. LLIf any IP100H settings have been changed, you must reboot it. [Common Settings]-[ID List] 1 2 This is an example when group 1 is selected in the [ID List Common
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 131
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu [Common Settings]-[ID List] ■■ID List Enters target IDs in the group that is selected in the "ID List Common Settings" field. LLYou can enter up to 50 target IDs in each group. 1 2 3 4 5 6 7 This is an example when group 1 is selected
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 132
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu ■■ID List Entries The list of entered Group Calls. [Common Settings]-[ID List] 12 3 This is an example when group 1 is selected in the [ID List Common Setting] field. If the name is not edited, displays only the item name. 1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 133
    . (This is only an example.) Message Group Number �� Select the group number to between 1 and 100 enter the messages that the IP100Hs will use. LLWhen the group name or messages are registered in the group, they are displayed as shown below. ■■Message Group Detail Enters the group
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 134
    Settings]-[Message] ■■Save or Write the Message Setting You can save a message file on your PC or load a message file to the IP1000C. LLIf any IP100H settings have been changed, you must reboot it. 1 2 This is an example when group 1 is selected in the [Message Group] field. If the name is
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 135
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu ■■Messages Enter messages in the group that is selected in the "Message Group" field. You can transmit fixed message of up to 32 characters. LLYou can enter up to 10 messages in each message group. [Common Settings]-[Message] 12 (This is only
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 136
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu [Common Settings]-[Status] ■■Status Settings Selects to register a status that the IP100Hs use. LLYou can programmed statuses of up to 32 characters. You can enter up to 10 statuses. LLIf any entries on this screen have been changed, you must
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 137
    the "Common Settings" item. [Common Settings]-[Profile] 1 (This is only an example.) 1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 138
    's Setting Uses the last wireless LAN setting that was set by the CS-IP100H or IP1000C. ••1 (Name) to 20 (Name) Select a number the Wireless LAN screen. Select an ID list that are commonly used by the IP100Hs in the group.  (Default: Disable) LLSelect an ID number that is registered
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 139
    IP1000C can quickly reply "No response" as a Target availability check. 8 Registration Retry Interval (If failed Enter a retry interval when the IP100H fails to register to the IP1000C, between 1 and 30 seconds. (Default: 10 (seconds)) 9 Number of Registration Retries (If failed Enter
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 140
    4 ABOUT THE SETTING SCREEN 9. [Common Settings] Menu ■■ Profile [Common Settings]-[Profile] 12 13 (This is only an example.) 12 Success Tone 13 Failure Tone Select a notice tone for a successful connection. (Default: Enable) LLWhen an individual call, Message call, Status call or
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 141
    sounds the notification beep. The received audio is muted until you reply the call. LLAfter pushing [PTT] on the IP100H, the mute will be released. Blinks Appears 10/3 12:57 All When the Pocket beep is active 10/3 12:57 All When the P-bell is
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 142
    Not Use" or "Tone 1" to "Tone 8." LLAfter each received call is completed, the IP100H will sound the specified beep. Select whether or not the IP100H sounds the Out of service area notice tone. (Default: Disable) When "Enable" is selected, the IP100H sounds the notice tone when it goes out the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 143
    or was called by. 10/8 16:57 All Destination ID (Call type) ••All operations Displays either IDs that the IP100H recently called, was called by or displayed ID list/History. Select whether the IP100H displays the Caller ID in the All call or Group call. (Default: Disable) •• Disable When the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 144
    26 (This is only an example.) 22 Date Format Select a date format to display on the IP100H's standby screen.  (Default: MM/DD) You can select "MM/DD," "DD/MM," " goes out. Enter a time between 0 and 600 seconds that the IP100H will return to the standby mode after a received signal from a
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 145
    is received than the finished call. After the Talk back timer has passed, a new call can be received. •• Disable Accepts to receive a new call after your current call is finished. Select whether or not the IP100H uses the Time-out timer.  (Default: Disable) LLWhen "Enable" is selected, the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 146
    34
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 147
    the button, you can register a consecutive Profiles collectively. LLIf a Profile is already registered, "Overwrite the entry" is displayed. Selects the default settings or the programmed settings to refer to.  (Default: Default) 4-93
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 148
    10. [Destination Settings] Menu [Destination Settings]-[Destination Setting] ■■Destination Setting Call Type: All Set the destinations to call all of the IP100Hs or IP100FSs in the tenant through the Internet. LLThis screen is displayed when clicking on the [List of Destination Setting
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 149
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu ■■Destination Setting Call Type: All [Destination Settings]-[Destination Setting] 1 2 3 45 (These are examples when clicking on the [List of Destination Setting Entries (All Call)] field.) 3 Additional Controller �� Select
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 150
    the operation type. Simplex operation When the Simpex is selected, the called station cannot reply until the caller station stops transmitting. Wireless access point IP1000C IP100H IP100H Full-duplex operation Wireless access point IP100FS (Remote communicator) IP1000C
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 151
    (These are examples when the "Call Type" item is set to "Group.") 7 Transceiver Selection �� Click to select the IP100H or IP100FS which belong to the group. LLOnly the IP100Hs or IP100FSs that are registered in the [Transceiver Registration] screen are listed. LLBy clicking the [All] box, you can
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 152
    on the [ID List] screen. LLPush [FUNC] on the IP100H, and then select the Talkgroup number to call the same Talkgroup members. When OFF is selected in the IP100H, the standby screen returns to the usual screen. Talkgroup 00202 Talkgroup 2
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 153
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu ■■ Destination Setting Call Type: Talkroup [Destination Settings]-[Destination Setting] 1 2 3 4 5 6 7 8 9 10 11 (These are examples when the "Call Type" item is set to "Talkgroup.") 5 Talkgroup Type When "Multiplex Talkgroup" is
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 154
    the operation type. Simplex operation LLWhen the Simpex is selected, the called station cannot reply until the caller station stops transmitting. Wireless access point IP1000C IP100H IP100H Full-duplex operation Wireless access point IP100FS (Remote communicator) IP1000C
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 155
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu ■■ Destination Setting Call Type: Talkroup [Destination Settings]-[Destination Setting] 1 2 3 4 5 6 7 8 9 10 11 (These are examples when the "Call Type" item is set to "Talkgroup.") 7 Talkgroup Call for IP100FS 8 Callee ID for IP100FS
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 156
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu [Destination Settings]-[Destination Setting] ■■ Destination Setting Call Type: Individual Set the destinations to call the group through the Internet. LLThe items on the [Destination Setting] screen differ depending on the Call type
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 157
    [RoIP Server Setting] menu. 6
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 158
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu [Destination Settings]-[Destination Setting] ■■List of Destination Setting Entries (All Call) Click to edit the setting on the [Destination Setting] field. (This is only an example.) ■■List of Destination Setting Entries (Group Call)
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 159
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu [Destination Settings]-[Destination Setting] ■■List of Destination Setting Entries (Talkgroup Call) The list of the registered Talkgroup Calls. 1 (This is only an example.) 1 Selection Box 2
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 160
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu [Destination Settings]-[Destination Setting] ■■List of Destination Setting Entries (Management Talkgroup Call) The list of the registered Management Talkgroup (Multiplex Talkgroup) Calls. 1 (This is only an example.) 1 Selection Box 2
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 161
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu [Destination Settings]-[Destination Setting] ■■List of Destination Setting Entries (Individual Call) The list of the registered Individual Calls. 1 23 45 (This is only an example.) 1 Selection Box 2
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 162
    4 ABOUT THE SETTING SCREEN 10. [Destination Settings] Menu [Destination Settings]-[Destination Setting] ■■List of Destination Setting Entries (Telephone) The list of the registered Phone Calls. 1 (This is only an example.) 1 Selection Box 2
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 163
    Destination IDs. By clicking , you can register consecutive Destination IDs collectively. LLIf a ID is already registered, "Override the settings" is displayed. Select the programmed setting to refer to. 4-109
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 164
    administrator login ID ("admin"). Enter the current password, when you change it. (Default: admin) LLThe entered characters are displayed as an * (asterisk) or a • (dot). Enter a new password up to 31 characters. LLThe entered characters are displayed as an * (asterisk) or a • (dot). Enter the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 165
    ] Menu ■■Date and Time You can set the IP1000C's internal clock time. (See Section 3 for details.) [Management]-[Date and Time] 1 2 1 Current Time 2 Manually Set Time 3
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 166
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■Time Zone Select the appropriate Time Zone. [Management]-[Date and Time] 1 2 1 Time Zone 2 Use Daylight Savings Time Select the appropriate Time Zone. (Default: Etc/UTC) Select "Disable" if not necessary. (Default: Enable) LLIf "Enable"
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 167
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu [Management]-[Date and Time] ■■NTP The Automatic Clock Synchronize function automatically synchronizes the internal clock with the time server (NTP). LLTo use this function, an internet connection and default gateway settings are necessary. 1 2 3
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 168
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu [Management]-[Date and Time] ■■SNTP Server The SNTP server is for our RoIP device which have no route to an external Time server (NTP). LLTo use this function, an internet connection and default gateway settings are necessary. 1 23 1 SNTP Server
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 169
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■SYSLOG Select the information to be saved to the SYSLOG host. [Management]-[SYSLOG] 1 2 3 4 5 6 1 DEBUG 2 INFO 3 NOTICE 4 Host IP Address 5
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 170
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■SNMP Configure the SNMP function. [Management]-[SNMP] 1 2 3 4 5 6 1 SNMP 2 Community Name (GET) � 3 System Location 4 System Contact 5
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 171
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■USB Select the USB flash drive option. [Management]-[USB] 1 2 3 4 1 USB Flash Drive 2 USB Access Permission � 3
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 172
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■Ping Test Run the Ping test. [Management]-[Network Test] 1 2 3 4 5 1 Host 2 Number of Times 3 Packet Size 4 Timeout 5
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 173
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■Traceroute Test Run the Traceroute test. [Management]-[Network Test] 1 2 3 4 5 1 Node 2 Max Hop Count 3 Timeout 4 DNS Lookup 5
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 174
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu [Management]-[Reboot] ■■Reboot Click to reboot the IP1000C. LLWhen clicking , the "Do you want to reboot the system?" message appears. Click to continue. 4-120
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 175
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■Settings Backup Save the IP1000C's settings to a PC as a backup. [Management]-[Settings Backup/Restore] Save to File Click to save the settings to a PC as a backup file (Extension: sav). See the topic below to load the saved file into
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 176
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu [Management]-[Settings Backup/Restore] ■■Online Settings You can remotely configure the IP1000C, through the secured network path. LLAn SFTP server is required for this function. 1 2 3 4 5 6 78 1 Online Settings 2 Sever Host Name 3
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 177
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■List of Settings Displays the changed settings. Note: The list is clear when the IP1000C is initialized. [Management]-[Settings Backup/Restore] (This is only an example.) 4-123
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 178
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu ■■Factory Defaults Click to return all settings to the factory default. [Management]-[Factory Defaults] LLIf you cannot access the IP1000C's setting screen, initialize the IP1000C using the button. See page 5-4 for details. NOTE:
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 179
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu [Management]-[Firmware Update] NOTE: ••NEVER turn OFF the power until the updating has been completed. Otherwise, the IP1000C may be damaged. ••Ask your dealer for updated function or specification details. ■■Firmware Status Displays the firmware
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 180
    4 ABOUT THE SETTING SCREEN 11. [Management] Menu [Management]-[Firmware Update] ■■Online Update Downloads the firmware through the internet, and automatically updates it. Note: To use this function, an internet connection, DNS and default gateway settings are necessary. Check for Updates
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 181
    to automatically update the firmware. Click to apply the entries. Click to restore the settings. LLYou cannot restore after clicking . ■■Manual Update The firmware can be updated using the saved firmware. 1 2 1 Select the update file �� 2 Firmware Update Click to select the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 182
    MAINTENANCE 5 Section 1. How to save the IP1000C's setting to a PC 5-2 MMSaving the setting...5-2 2. How to load the saved file to an IP1000C 5-3 MMReloading the settings file into the IP1000C 5-3 3. How to initialize the settings to the factory default 5-4 4. How to update the firmware...5-6
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 183
    5 MAINTENANCE 1. How to save the IP1000C's setting to a PC You can save the IP1000C's settings of its setting screen to a PC or USB flash drive. The saved settings can be used to recover the configuration. LLThe settings can be directly loaded into the IP1000C from the USB flash drive. ■■Saving
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 184
    5 MAINTENANCE 2. How to load the saved file to an IP1000C You can load the IP1000C's settings from a PC. LLThe settings can be directly loaded into the IP1000C from a USB flash drive. (p. 5-12) ■■Reloading the settings file into the IP1000C 1 Click [Management], then [Settings Backup/Restore].
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 185
    5 MAINTENANCE 3. How to initialize the settings to the factory default There two ways to initialize the IP1000C. LLSet the IP1000C's IP address again after the IP1000C is initialized. A: Using the button. If you cannot access the IP1000C setting screen, initialize the IP1000C by pushing the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 186
    5 MAINTENANCE 3. How to initialize the settings to the factory default B: Using the IP1000C's setting screen 1 Click [Management], then [Factory Defaults]. ••The [Factory Defaults] screen appears. 2 Click . ••The warning window appears. 3 Click . ••The IP1000C automatically
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 187
    . ••If the firewall is running, stop it before updating the firmware. If you want to stop the firewall, ask your network administrator for the detail. ••Icom is not responsible on the consequence of the updating the firmware. 5-6
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 188
    be returned to their default after the firmware update. Check the Icom website for details. LLRestricting access to the setting screen is recommended. (p. 3-2) 1 Download a new firmware (extension: "dat") from the Icom website. 2 Click the [Management] menu, then [Firmware Update]. ••The [Firmware
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 189
    5 MAINTENANCE 4. How to update the firmware B: Use the Firmware Update function When [MSG] lights green, a firmware update is ready. See the "Precautions" leaflet for details. LLTo use this function, an internet connection, DNS and default gateway settings are necessary. LLWe recommend to save the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 190
    setting data from a USB flash drive to the IP1000C, the originally programmed setting data is automatically saved as "bakdata.sav" in the USB USB flash drive, the firmware and setting data are sequentially updated. Supported USB specification: Interface: USB 2.0 Device: USB flash drive (USB Mass
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 191
    restore. See page 5-2 for details. [Management] (menu) > [Settings Backup/Restore] (screen) > [Settings Restore] (field) The firmware file, which is downloaded from Icom website, must be saved as "firmware.dat" on the flash drive. [About the Automatic Settings Backup function] The latest 10 backup
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 192
    5 MAINTENANCE 5. About the Automatic Restore using a USB flash drive [How to clone the settings and the firmware using a USB flash drive.] A USB flash drive can contain settings and firmware files for different IP1000Cs. You need to create folders, whose names are each IP1000C's LAN MAC address (p.
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 193
    5 MAINTENANCE 6. How to restore the configuration using a USB flash drive You can clone the settings to the other IP1000Cs. It is convenient when you sequentially configure multiple IP1000Cs. Note: Before using a USB flash drive, see page 5-9. ■■Saving the settings file to a USB flash drive 1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 194
    5 MAINTENANCE 6. How to restore the configuration using a USB flash drive ■■Loading the settings from the USB flash drive 1 Remove the USB flash drive from the PC appropriately. 2 Prepare the IP1000C to load the settings. 3 Turn OFF the power. Note: Turn OFF the IP1000C's power, before
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 195
    5 MAINTENANCE 6. How to restore the configuration using a USB flash drive ■■Loading the settings from the USB flash drive 5 When the all data has been loaded, the [USB] LED turns OFF, and the IP1000C automatically reboots. Verify that the [PWR] LED lights green, then turn OFF the power. Then
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 196
    update can be done by using a USB flash drive. Note: Before using a USB flash drive, see page 5-9. ■■Updating the firmware 1 Download a new firmware (extension: "dat") from Icom website. 2 Insert the USB flash drive to the PC. 3 Select the root directory of the USB flash drive, and save the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 197
    5 MAINTENANCE 7. How to update the firmware using a USB flash drive ■■Updating the firmware 8 All LEDs light orange while the firmware update is in progress. Note: NEVER remove the USB flash drive or turn OFF the IP1000C's power. Lights orange while updating the firmware. 9 When the update has
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 198
    FOR YOUR INFORMATION 6 Section 1. Trouble shooting...6-2 2. How to connect to the IP1000C using Telnet 6-4 MMHow to connect...6-4 MMHow to use the [CONSOLE] port 6-4 MMAbout Telnet commands...6-4 3. Specifications...6-5 MMGeneral...6-5 MMCommunication Interfaces...6-5 6-1
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 199
    YOUR INFORMATION 1. Trouble shooting If the IP1000C seems to be malfunctioning, please check the following before sending it to a service center. The [ the IP1000C's setting screen. ••The PC's IP address is incorrect. - Manually set the PC's IP address after you set the IP1000C to the default
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 200
    YOUR INFORMATION 1. Trouble shooting The IP100H displays the "Out of range" icon or "Connecting..." ••The distance between the IP100H and its of the access point. - Using the cloning software CS-IP100H, check and modify the wireless LAN settings of the IP100H. ••In the 5 GHz band operation, the
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 201
    6 FOR YOUR INFORMATION 2. How to connect to the IP1000C using Telnet For Windows® 10: Before performing the following procedure, turn ON [Telnet Client] from the screen that is displayed when "Turn Windows features on or off" is entered in the search box on the taskbar. ■■How to connect 1. Start
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 202
    6 FOR YOUR INFORMATION 3. Specifications Note: All specifications are subject to change without notice. ■■General Power supply: 12 V DC ±10% [Plug polarity: ] Less than 15 Watts Usable condition: Temperature 0 to +40°C; +32 to +104°F, Humidity 5-95% (At no condensation) Dimension: 
  • Icom IP100H | Instruction Manual ver. 2.30 - Page 203
    A7125-3EX-8 Printed in Japan © 2014-2020 Icom Inc. Jun. 2020 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203

INSTRUCTION MANUAL
IP1000C
IP ADVANCED RADIO SYSTEM
CONTROLLER
INTRODUCTION
1 BEFORE USING THE IP1000C
2 SETTING UP THE IP1000C SYSTEM
3 OTHER BASIC FUNCTIONS
4 ABOUT THE SETTING SCREEN
5 MAINTENANCE
6 FOR YOUR INFORMATION