Icom IP100H Instruction Manual ver. 2.30 - Page 71

[RoIP Settings] Menu, Additional Controller Settings

Page 71 highlights

4 ABOUT THE SETTING SCREEN 5. [RoIP Settings] Menu [RoIP Settings]-[Additional Controller Settings] ■■Additional Controller Settings Configure the Additional Controller Settings. 1 2 3 Example: The default of the [Additional Controller] item is "Disable." 2 and 3 appear when selecting "Enable" in the [Additional Controller] item. 1 Additional Controller �� Select "Enable" in the [Additional Controller] item to communicate with additional Controllers. (Default: Disable) When selecting "Enable," you can communicate with the IP100Hs and the IP100FS registered to additional controllers. LLRegister the destination controller on the [Additional Controller Link] item in the [RoIP Server Settings] menu. LLWhen using this Additional Controller Settings, you can link to the bridge mode's VE-PG3 for communication. 2 Controller Mode Select "Master" for one master Controller. Select [Sub] for the other Controllers (up to 10 Sub Controllers can be set). (Default: Sub) When several Controllers are linked and use All call or Group call between the controllers, the IP1000C whose Controller mode is set to "Sub" cannot link to the bridge mode's VE-PG3 to additional controller. In that case, the VE-PG3 must be linked to the IP1000C whose Controller mode is set to "Master." 3 Service Port Number �� Enter the port number for receiving audio signals. Range: "2" to "65534" (only even numbers) (Default: 32000) The set port number (RTP) and the port number +1 (RTCP) are used for the communication. LLThis number is also used for the caller port number. LLDo not set the port number which has already been used by another connection setting. 4-17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203

4
ABOUT THE SETTING SCREEN
4-17
5. [RoIP Settings] Menu
[RoIP Settings]–[Additional Controller Settings]
Additional Controller Settings
Configure the Additional Controller Settings.
1
Additional Controller ��
Select “Enable” in the [Additional Controller] item to communicate with
additional Controllers.
(Default: Disable)
When selecting “Enable,” you can communicate with the IP100Hs and
the IP100FS registered to additional controllers.
L
Register the destination controller on the [Additional Controller Link] item in
the [RoIP Server Settings] menu.
L
When using this Additional Controller Settings, you can link to the bridge
mode’s VE-PG3 for communication.
2
Controller Mode �����
Select “Master” for one master Controller. Select [Sub] for the other
Controllers (up to 10 Sub Controllers can be set).
(Default: Sub)
When several Controllers are linked and use All call or Group call
between the controllers, the IP1000C whose Controller mode is set to
“Sub” cannot link to the bridge mode’s VE-PG3 to additional controller.
In that case, the VE-PG3 must be linked to the IP1000C whose
Controller mode is set to “Master.”
3
Service Port Number ��
Enter the port number for receiving audio signals.
Range: “2” to “65534” (only even numbers)
(Default: 32000)
The set port number (RTP) and the port number +1 (RTCP) are used
for the communication.
L
This number is also used for the caller port number.
L
Do not set the port number which has already been used by another
connection setting.
Example: The default of the [Additional Controller] item is “Disable.”
2
and
3
appear when selecting “Enable” in the [Additional Controller] item.
1
2
3