Intel BB5520UR Product Specification - Page 166
Appendix C: BMC Sensor Tables, Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS, Revision 1.
View all Intel BB5520UR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 166 highlights
Appendix C: BMC Sensor Tables Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Table 82. Integrated BMC Core Sensors Full Sensor Name (Sensor name in SDR) Power Unit Status (Pwr Unit Status) Power Unit Redundancy1 (Pwr Unit Redund) Sensor # Platform Applicability 01h All 02h Chassisspecific Sensor Type Power Unit 09h Power Unit 09h Event/Reading Event Offset Type Triggers Contrib. To System Status Assert/De -assert Readable Value/Offs ets Event Data 00 - Power down OK 04 - A/C lost Sensor Specific 6Fh 05 - Soft power control failure As and De - Trig Offset Fatal 06 - Power unit failure 00 - Fully Redundant OK 01 - Redundancy lost Degraded 02 - Redundancy degraded Degraded 03 - Non- redundant: sufficient resources. Degraded Generic 0Bh Transition from full redundant state. As and De - Trig Offset 04 - Nonredundant: sufficient resources. Transition from insufficient state. Degraded 05 - Nonredundant: insufficient resources Fatal Rearm A A Standby X X 152 Revision 1.8 Intel order number E39529-013