Intel BB5520UR Product Specification - Page 171

PS1 Status, PS2 Status, PS1 Power In, PS2 Power In, PS1 Curr Out, PS2 Curr Out

Page 171 highlights

Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Appendix C: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Power Supply 1 Status (PS1 Status) 50h Chassisspecific Power Supply 2 Status (PS2 Status) 51h Chassisspecific Power Supply 1 AC Power Input 52h (PS1 Power In) Power Supply 2 AC Power Input 53h (PS2 Power In) Power Supply 1 +12V % of Maximum Current Output 54h (PS1 Curr Out %) Power Supply 2 +12V % of Maximum Current Output 55h (PS2 Curr Out %) Chassisspecific Chassisspecific Chassisspecific Chassisspecific Sensor Type Power Supply 08h Power Supply 08h Other Units 0Bh Other Units 0Bh Current 03h Current 03h Event/Reading Event Offset Type Triggers Sensor Specific 6Fh Sensor Specific 6Fh Threshold 01h 07 - Redundant degraded from non-redundant 00 - Presence 01 - Failure 02 - Predictive Failure 03 - A/C lost 06 - Configuration error 00 - Presence 01 - Failure 02 - Predictive Failure 03 - A/C lost 06 - Configuration error [u] [c,nc] Threshold 01h Threshold 01h Threshold 01h [u] [c,nc] [u] [c,nc] [u] [c,nc] Contrib. To System Status Assert/De -assert Readable Value/Offs ets Event Data Degraded OK Degraded Degraded Degraded As and De - Trig Offset OK OK Degraded Degraded Degraded As and De - Trig Offset OK nc = Degraded As and De Analog R, T c = Non-fatal nc = Degraded As and De Analog R, T c = Non-fatal nc = Degraded As and De Analog R, T c = Non-fatal nc = Degraded As and De Analog R, T c = Non-fatal Rearm A A A A A A Standby X X X X X X Revision 1.8 157 Intel order number E39529-013

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Appendix C: BMC Sensor Tables
Revision 1.8
Intel order number E39529-013
157
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
07 - Redundant
degraded from
non-redundant
Degraded
Power Supply 1 Status
(PS1 Status)
50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig Offset
A
X
01 - Failure
Degraded
02 – Predictive
Failure
Degraded
03 - A/C lost
Degraded
06 –
Configuration
error
OK
Power Supply 2 Status
(PS2 Status)
51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig Offset
A
X
01 - Failure
Degraded
02 – Predictive
Failure
Degraded
03 - A/C lost
Degraded
06 –
Configuration
error
OK
Power Supply 1
AC Power Input
(PS1 Power In)
52h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2
AC Power Input
(PS2 Power In)
53h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 1 +12V % of
Maximum Current Output
(PS1 Curr Out %)
54h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Power Supply 2 +12V % of
Maximum Current Output
(PS2 Curr Out %)
55h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X