Calculate RFID Tag Position, Wizard > Calibration > RFID, Calibration, Enable
View all Intermec PM23c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Chapter 2 - Set Up the Printer 2 From the Main Menu, select Wizard > Calibration > RFID Calibration. 3 To enable the RFID module, select Enable. 4 Load the RFID media. 5 Select OK. When the calibration is complete, the printer displays the RFID Tag Position and Output Power (UHF inlays, only). Calculate RFID Tag Position You can perform a manual calculation to come up with an estimate of the RFID Tag Position. Because this value is an estimate, you may need to slightly adjust the calculated value to achieve the best results. Note: You do not need to calculate the Tag Position value for the PM23c printer. By default, the Tag Position is set to -13.5 mm and the yAntDist is 135 mm (pivoted antenna) or 136 mm (flat antenna). 1 Make sure Start Adjust and Stop Adjust are set to 0. 2 Measure the yChip value, which is the distance between the RFID chip and the media edge aligned with the tear bar. -BCFMUPQ PGGPSN .FEJBFEHF BMJHOFEXJUI UFBSCBS /FYUMBCFM 3'*%DIJQ Z$IJQ 42 PM23c, PM43, and PM43c Mid-Range Printer User Manual