Lexmark X264 Service Manual - Page 113
Sensor2 test, Select, Starting Test, Sensor 2: Closed
View all Lexmark X264 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
7013-XXX Sensor2 test This test verifies the functionality of scan sensor 2. To test this sensor, perform the following steps: 1. In the sensor test menu, press or to scroll to the Sensor 2 test. 2. Press Select ( ). Starting Test displays. Sensor 2: Closed displays. 3. Lift the ADF top cover, and close the ADF cover sensor (A) by pressing down on the ADF sensor actuator with a small flatblade screwdriver. A 4. Move the Sensor 2 actuator by inserting a small screwdriver into the hole (B) and gently toggling the actuator. Sensor 2: Open should display if the sensor is working properly. B 5. Press Back ( ) to exit the test and return to the Scanner sensor tests. Diagnostic aids 3-21
Diagnostic aids
3-21
7013-
XXX
Sensor2 test
This test verifies the functionality of scan sensor 2. To test this sensor, perform the following steps:
1.
In the sensor test menu, press
or
to scroll to the Sensor 2 test.
2.
Press
Select
(
).
Starting Test
displays.
Sensor 2: Closed
displays.
3.
Lift the ADF top cover, and close the ADF cover sensor (A) by pressing down on the ADF sensor actuator
with a small flatblade screwdriver.
4.
Move the Sensor 2 actuator by inserting a small screwdriver into the hole (B) and gently toggling the
actuator.
Sensor 2: Open
should display if the sensor is working properly.
5.
Press
Back
(
) to exit the test and return to the Scanner sensor tests.
A