Lexmark X264 Service Manual - Page 229

Preventive maintenance, Safety inspection guide, Lubrication specifications, Maintenance kits

Page 229 highlights

7013-XXX 6. Preventive maintenance This chapter describes procedures for printer preventive maintenance. Follow these recommendations to help prevent problems and maintain optimum performance. Safety inspection guide The purpose of this inspection guide is to aid you in identifying unsafe conditions. If any unsafe conditions exist, then find out how serious the hazard could be and if you can continue before you correct the hazard. Check the following items: • Damaged, missing, or altered parts, especially in the area of the On/Off switch and the power supply • Damaged, missing, or altered covers, especially in the area of the top cover and the power supply cover • Possible safety exposure from any non-Lexmark attachments Lubrication specifications FRUs are typically lubricated as needed from the factory. If not, then lubricate only when parts are replaced or as needed, not on a scheduled basis. Use of lubricants other than those specified can cause premature failure. Some unauthorized lubricants may chemically attack parts. Use P/N 99A0394 (Nyogel 744) to lubricate appropriate areas. Lubricate gears that were lubricated in the original part. Maintenance kits Maintenance kits Description Low voltage (110 V) maintenance kit Note: The fuser maintenance kit installation is recommended every 120,000 pages. Note: The kit includes: • Fuser (P/N 40X5344) • Tray 1 ACM feed tires (P/N 40X5451) • Transfer roll (P/N 40X5364) High voltage (220 V) maintenance kit Note: The fuser maintenance kit installation is recommended every 120,000 pages. Note: The kit includes: • Fuser (P/N 40X5345) • Tray 1 ACM feed tires (P/N 40X5451) Transfer roll (P/N 40X5364) Part number 40X5400 40X5401 Preventive maintenance 6-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250

Preventive maintenance
6-1
7013-XXX
6.
Preventive maintenance
This chapter describes procedures for printer preventive maintenance. Follow these recommendations to help
prevent problems and maintain optimum performance.
Safety inspection guide
The purpose of this inspection guide is to aid you in identifying unsafe conditions.
If any unsafe conditions exist, then find out how serious the hazard could be and if you can continue before you
correct the hazard.
Check the following items:
Damaged, missing, or altered parts, especially in the area of the On/Off switch and the power supply
Damaged, missing, or altered covers, especially in the area of the top cover and the power supply cover
Possible safety exposure from any non-Lexmark attachments
Lubrication specifications
FRUs are typically lubricated as needed from the factory. If not, then lubricate only when parts are replaced or
as needed, not on a scheduled basis. Use of lubricants other than those specified can cause premature failure.
Some unauthorized lubricants may chemically attack parts. Use P/N 99A0394 (Nyogel 744) to lubricate
appropriate areas. Lubricate gears that were lubricated in the original part.
Maintenance kits
Maintenance kits
Description
Part number
Low voltage (110 V) maintenance kit
Note: The fuser maintenance kit installation is
recommended every 120,000 pages.
Note: The kit includes:
Fuser (P/N 40X5344)
Tray 1 ACM feed tires (P/N 40X5451)
Transfer roll (P/N 40X5364)
40X5400
High voltage (220 V) maintenance kit
Note: The fuser maintenance kit installation is
recommended every 120,000 pages.
Note: The kit includes:
Fuser (P/N 40X5345)
Tray 1 ACM feed tires (P/N 40X5451)
Transfer roll (P/N 40X5364)
40X5401