Panasonic CS-E18SD3UAW service manual - Page 104
Technical data provided are based on the air conditioner running under, rated frequency.
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 104 highlights
17.2 Technical data provided are based on the air conditioner running under rated frequency. 17.2.1 Cool Mode Performance Data Unit setting: Standard piping length, Hi Fan, Cool mode at 60.8°F Voltage: 208V/230V 17.2.1.1 CS-E9SD3UAW/CU-E9SD3UA Indoor (°C/°F) DB WB -20 (-4) TC SHC IP 27 (80.6) 19 (66.2) 22 (71.6) 2966 3134 2655 1887 508 540 23 (73.4) 16 (60.8) 18 (64.4) 2776 2920 2748 1880 485 498 20 (68) 13 (55.4) 16 (60.8) 2637 2718 2611 1870 525 535 TC 2966 3134 2776 2920 2637 2718 Outdoor DB (°C/°F) -10 (14) SHC IP TC 2655 516 2952 1887 549 3153 2748 493 2683 1880 506 2827 2611 534 2543 1870 544 2725 0 (32) SHC 2679 1915 2656 1848 2518 1856 5 (41) IP TC SHC IP 504 3013 2734 476 517 3404 2034 386 527 3039 3008 424 530 2987 1945 447 547 2331 2308 375 525 2454 1751 355 Indoor (°C/°F) 16 (60.8) DB WB TC SHC IP 27 (80.6) 19 (66.2) 22 (71.6) 3135 3238 2665 1905 422 420 23 (73.4) 16 (60.8) 18 (64.4) 2781 2941 2753 1886 473 456 20 (68) 13 (55.4) 16 (60.8) 2061 2363 2040 1662 209 402 Outdoor DB (°C/°F) 25 (77) 35 (95) 46 (114.8) TC SHC IP TC SHC IP TC SHC IP 2770 2455 617 2640 2482 690 2166 1920 829 3023 1724 590 2811 1723 678 2364 1349 792 2509 2484 633 2433 2409 699 1962 1943 850 2757 1738 616 2495 1778 690 2156 1360 827 2042 2022 478 2236 2213 702 1516 1501 642 2455 1701 630 2272 1707 695 1920 1330 847 (Dry bulb value based on 46% humidity) 17.2.1.2 CS-E12SD3UAW/CU-E12SD3UA Indoor (°C/°F) DB WB -20 (-4) TC SHC IP 27 (80.6) 19 (66.2) 22 (71.6) 3775 3989 3343 2377 678 720 23 (73.4) 16 (60.8) 18 (64.4) 3533 3716 3497 2368 647 664 20 (68) 13 (55.4) 16 (60.8) 3357 3459 3323 2354 700 714 TC 3775 3989 3533 3716 3357 3459 Outdoor DB (°C/°F) -10 (14) SHC IP TC 3343 689 3757 2377 732 4013 3497 657 3414 2368 674 3599 3323 712 3237 2354 725 3468 0 (32) SHC 3373 2411 3380 2327 3205 2337 5 (41) IP TC SHC IP 671 3835 3443 635 689 4333 2561 515 703 3867 3829 565 706 3802 2449 596 729 2967 2937 500 700 3123 2204 474 Indoor (°C/°F) DB WB 16 (60.8) TC SHC IP 27 (80.6) 19 (66.2) 22 (71.6) 3990 4121 3356 2399 563 560 23 (73.4) 16 (60.8) 18 (64.4) 3539 3743 3503 2375 631 608 20 (68) 13 (55.4) 16 (60.8) 2623 3007 2596 2092 279 536 Outdoor DB (°C/°F) 25 (77) 35 (95) 46 (114.8) TC SHC IP TC SHC IP TC SHC IP 3525 3091 823 3360 3125 920 2757 2564 1105 3847 2171 786 3577 2170 904 2935 1780 1086 3193 3161 844 3096 3065 932 2541 2515 1120 3508 2189 821 3176 2239 919 2606 1837 1104 2599 2573 638 2845 2817 935 2335 2311 1123 3125 2142 841 2892 2149 926 2373 1764 1113 (Dry bulb value based on 46% humidity) 104