12.2 Quiet Operation (Cooling Mode/Cooling Area of Soft Dry Mode) A. Purpose To provide quiet cooling operation compare to normal operation. B. Control condition a. Quiet operation start condition When "quiet" button at remote control is pressed. Quiet LED illuminates. b. Quiet operation stop condition 1 When one of the following conditions is satisfied, quiet operation stops: a. Powerful button is pressed. b. Stop by OFF/ON switch. c. Timer "off" activates. d. Quiet button is pressed again. 2 When quiet operation is stopped, operation is shifted to normal operation with previous setting. 3 When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed. 4 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode. 5 During quiet operation, if timer "on" activates, quiet operation maintains. 6 After off, when on back, quiet operation is not memorised. C. Control contents 1 Auto fan speed is changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of Hi, Me, Lo for 3dB. 2 Manual fan speed for quiet operation is 1 step from setting fan speed. 3 Compressor frequency reduced. 12.2.1 Quiet operation (Heating) A. Purpose To provide quiet heating operation compare to normal operation. B. Control condition a. Quiet operation start condition When "quiet" button at remote control is pressed. Quiet LED illuminates. b. Quiet operation stop condition 1 When one of the following conditions is satisfied, quiet operation stops: a. Powerful button is pressed. b. Stop by OFF/ON switch. c. Timer "off" activates. d. Quiet button is pressed again. 2 When quiet operation is stopped, operation is shifted to normal operation with previous setting. 3 When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed. 4 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except fan only mode. 5 During quiet operation, if timer "on" activates, quiet operation maintains. 6 After off, when on back, quiet operation is not memorised. C. Control contents a. Fan Speed Auto Indoor FM RPM depends on pipe temperature sensor of indoor heat exchanger. Auto fan speed is changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of Hi, Me, Lo for 3dB. b. Fan Speed Manual Manual fan speed for quiet operation is - 1 step from setting fan speed. c. Compressor frequency reduced. 51
![](/manual_guide/products/panasonic-e9sd3ua-service-manual-80b38e9/51.png)