Panasonic CS-E18SD3UAW service manual - Page 56
Protection Control For Cooling & Soft Dry Operation
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
13.1.4 IPM (Power transistor) Prevention Control Overheating Prevention Control 1 When the IPM temperature rises to 248°F, compressor operation will stop immediately. 2 Compressor operation restarts after three minutes the temperature decreases to 230°F. DC Peak Current Control 1 When electric current to IPM exceeds set value of 30.0 ± 5.0 A, the compressor will stop operate. Then, operation will restart after three minutes. 2 If the set value is exceeded again more than 30 seconds after the compressor starts, the operation will restart after two minutes. 3 If the set value is exceeded again within 30 seconds after the compressor starts, the operation will restart after one minute. If this condition repeats continuously for seven times, all indoor and outdoor relays will be cut off. 13.1.5 Compressor Overheating Prevention Control Instructed frequency for compressor operation will be regulated by compressor top temperature. The changes of frequency are as below figure. If compressor temperature exceeds 224.6°F, compressor will be stop, occurs 4 times per 20 minutes, timer LED will be blinking ("F97" is to be confirmed). 224.6ºF 217.4ºF 212ºF Compressor = OFF Compressor Frequency Reduce Compressor Frequency Maintain Free Comp. top temperature 197.6ºF 195.8ºF 194ºF 13.2 Protection Control For Cooling & Soft Dry Operation 13.2.1 Outdoor Air Temperature Control The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the diagram below. This control will begin 1 minute after the compressor starts. Compressor frequency will adjust base on Outdoor Air Temperature. 77ºF Free Limited frequency Outdoor Air Temperature 71.6ºF 56