Panasonic CS-E18SD3UAW service manual - Page 63

Remote Controller Room Temperature Thermoshift Control

Page 63 highlights

14.4 Remote Controller Room Temperature Thermoshift Control 14.4.1 Purpose To prevent not enough or over supply of cooling and heating capacity by adjusting the Room Temperature thermoshift by using remote controller. Temperature can be adjusted are -3°C (-5.4°F), -2°C (-3.6°F), -1°C (-1.8°F), 0°C (0°F), 1°C (1.8°F), 2°C (3.6°F), 3°C (5.4°F) Thermoshift adjusted by Remote controller will be stored into EEPROM and added into the final target setting temperature. Function selection added to enable and disable this control. 14.4.2 Control method Heating mode (using remocon function 58) Normal display mode Press SW (t 0secs) Shift -3°C When SW pressed continuously for t 5secs to enter service zone & press SW's to choose function 58 (shift 0°C) Timer Up Down button Shift -1°C Shift 0°C Shift +1°C Shift +3°C Range = -3°C/-2°C/-1°C/0°C/+1°C/+2°C/+3°C Transmit shift code 1 Press SW, special setting is immediately cancelled and normal mode starts. 2 If no SW is pressed for 30secs, then special setting mode is cancelled and normal mode starts. 3 Under this function, only , , & SW's are effective. 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

63
14.4 Remote Controller Room Temperature Thermoshift Control
14.4.1
Purpose
To prevent not enough or over supply of cooling and heating capacity by adjusting the Room Temperature
thermoshift by using remote controller.
Temperature can be adjusted are -3°C (-5.4°F), -2°C (-3.6°F), -1°C (-1.8°F), 0°C (0°F), 1°C (1.8°F), 2°C (3.6°F),
3°C (5.4°F)
Thermoshift adjusted by Remote controller will be stored into EEPROM and added into the final target setting
temperature.
Function selection added to enable and disable this control.
14.4.2
Control method
Heating mode (using remocon function 58)
Normal display mode
Press
SW (t
0secs)
When
SW pressed continuously for t
5secs to enter service zone
& press
SW’s to choose function 58 (shift 0°C)
Range = -3°C/-2°C/-1°C/0°C/+1°C/+2°C/+3°C
Transmit shift code
Timer Up Down button
Shift -3°C
Shift -1°C
Shift 0°C
Shift +1°C
Shift +3°C
1
Press
SW, special setting is immediately cancelled and normal mode starts.
2
If no SW is pressed for 30secs, then special setting mode is cancelled and normal mode starts.
3
Under this function, only
,
,
&
SW’s are effective.