Panasonic CS-E18SD3UAW service manual - Page 63
Remote Controller Room Temperature Thermoshift Control
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
14.4 Remote Controller Room Temperature Thermoshift Control 14.4.1 Purpose To prevent not enough or over supply of cooling and heating capacity by adjusting the Room Temperature thermoshift by using remote controller. Temperature can be adjusted are -3°C (-5.4°F), -2°C (-3.6°F), -1°C (-1.8°F), 0°C (0°F), 1°C (1.8°F), 2°C (3.6°F), 3°C (5.4°F) Thermoshift adjusted by Remote controller will be stored into EEPROM and added into the final target setting temperature. Function selection added to enable and disable this control. 14.4.2 Control method Heating mode (using remocon function 58) Normal display mode Press SW (t 0secs) Shift -3°C When SW pressed continuously for t 5secs to enter service zone & press SW's to choose function 58 (shift 0°C) Timer Up Down button Shift -1°C Shift 0°C Shift +1°C Shift +3°C Range = -3°C/-2°C/-1°C/0°C/+1°C/+2°C/+3°C Transmit shift code 1 Press SW, special setting is immediately cancelled and normal mode starts. 2 If no SW is pressed for 30secs, then special setting mode is cancelled and normal mode starts. 3 Under this function, only , , & SW's are effective. 63