Panasonic CS-E18SD3UAW service manual - Page 110
Service Data
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
18. Service Data Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced heating mode. 18.1 Cool Mode Outdoor Air Temperature Characteristic 18.1.1 CS-E9SD3UAW CU-E9SD3UA Condition Indoor room temperature: 80.1°F Dry Bulb/66.9°F Wet Bulb Unit setting: Standard piping length, forced cooling at 60.8°F, Hi fan Compressor frequency: Rated for cooling operation Voltage: 208V/230V 208V 230V Current (A) 4.500 4.000 3.500 3.000 2.500 2.000 -4 6 16 26 36 46 56 66 76 86 96 106 116 Outdoor Air Temperature(゚F) Low Pressure (Psi) 159.000 157.000 155.000 153.000 151.000 149.000 147.000 145.000 143.000 141.000 -4 6 16 26 36 46 56 66 76 86 96 106 116 Outdoor Air Temperature(゚F) 97.000 95.000 93.000 91.000 89.000 87.000 85.000 -4 6 16 26 36 46 56 66 76 86 96 106 116 Outdoor Air Temperature(゚F) Outlet Air (゚F) 110