Panasonic CS-E18SD3UAW service manual - Page 81
H28 Outdoor Pipe Temperature Sensor Abnormality
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
15.5.10 H28 (Outdoor Pipe Temperature Sensor Abnormality) Malfunction Decision Conditions During startup and operation of cooling and heating, the temperatures detected by the outdoor pipe temperature sensor are used to determine sensor errors. Malfunction Caused Faulty connector connection. Faulty sensor. Faulty PCB. Troubleshooting When abnormality indication starts again Check the connector connection: ● Turn off the power ● Check the connector connection Caution For safety reason and to prevent component breakdown, always switch off the power before remove and connect the component. NO Is the connector connection normal? YES Check the outdoor heat exchanger temperature sensor: ● Plug out connector from the outdoor unit PCB ● Measure the resistance of the outdoor heat exchanger temperature sensor Is the measured resistance of the outdoor heat exchanger NO temperature sensor matches the value specified in its characteristic chart? YES ● Connector poor contact ● Correct the connection ● Defect in outdoor heat exchanger temperature sensor ● Replace the outdoor heat exchanger temperature sensor ● Defect in outdoor unit PCB ● Replace the outdoor unit PCB Sensor (Thermistor) Characteristics 70 1 Outdoor Air Sensor 60 2 Outdoor Heat Exchanger Sensor 50 40 1 30 2 20 10 0 14 32 50 68 86 104 122 Temperature (ºF) Resistance (kΩ) 81