Panasonic CS-E18SD3UAW service manual - Page 33

Installation Instruction

Page 33 highlights

11. Installation Instruction  IMPORTANT (ONLY FOR E9SD3UAW AND E12SD3UAW) This product has been designed and manufactured to meet ENERGY STAR® criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achive rated capacity and efficiency. Installation of this product should follow the manufacturer's refrigerant charging and air flow instructions. Failure to confirm proper charge and airflow may reduce energy efficiency and shorten equipment life. Attached Accessories No. Accessory part Remote control 1 2 Battery Remote control holder 3 4 Remote control holder fixing screw Remote control receiver 5 Qty. No. Accessory part Receiver fixing screw 1 6 (M4 x 39/64" (15.5 mm)) Clamper (band) 2 7 (for receiver cable fixing) Receiver cable 1 8 (6.56 ft (2 m)) Washer 2 9 (for suspension fitting) Flare insulator 1 0 (for gas pipe / liquid pipe connection) Qty. No. Accessory part Qty. Clamper (band) 2 ! (for flare & drain insulating 4 connection) 1 Drain hose @ (for unit & PVC pipe connection) 1 # Hose band (for drain hose connection) 1 L=131 1 8 $ Drain hose insulation (for drain pipe connection) 2 Clamper (band) 2 % (for power supply cord) * Be sure to fix the power supply cord 1 with clamper (band). ¥ Drain elbow 1 ■ Required Materials  Read the catalog and other technical materials and prepare the required materials.  Applicable piping kit Applicable piping kit CZ-3F5, 7BP CZ-4F5, 7, 10BP CZ-52F5, 7, 10BP Piping size Gas Liquid 3/8" (9.52 mm) 1/4" (6.35 mm) 1/2" (12.7 mm) 1/4" (6.35 mm) 5/8" (15.88 mm) 1/4" (6.35 mm)  Pipe size reducer (CZ-MA1P) for outdoor Multi connection CS-E12SD3UAW, CS-E18SD3UAW 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

33
11. Installation Instruction
IMPORTANT (ONLY FOR E9SD3UAW AND E12SD3UAW)
This product has been designed and manufactured to meet ENERGY STAR
®
criteria for energy efficiency when
matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to
achive rated capacity and efficiency. Installation of this product should follow the manufacturer’s refrigerant
charging and air flow instructions.
Failure to confirm proper charge and airflow may reduce energy
efficiency and shorten equipment life.
Attached Accessories
No.
Accessory part
Qty.
1
Remote control
1
2
Battery
2
3
Remote control holder
1
4
Remote control holder
fixing screw
2
5
Remote control receiver
1
No.
Accessory part
Qty.
6
Receiver fixing screw
(M4 x
39
/64" (15.5 mm))
2
7
Clamper (band)
(for receiver cable fixing)
1
8
Receiver cable
(6.56 ft (2 m))
1
9
Washer
(for suspension fitting)
8
0
Flare insulator
(for gas pipe / liquid pipe
connection)
2
No.
Accessory part
Qty.
!
Clamper (band)
(for flare & drain insulating
connection)
4
@
Drain hose
(for unit & PVC pipe
connection)
1
#
Hose band
(for drain hose connection)
1
$
Drain hose insulation
(for drain pipe connection)
2
%
Clamper (band)
(for power supply cord)
1
*
Be sure to fix the power supply cord
with clamper (band).
¥
Drain elbow
1
L=131
Required Materials
Read the catalog and other technical materials and prepare the required materials.
Applicable piping kit
Applicable piping kit
Piping size
Gas
Liquid
CZ-3F5, 7BP
3/8" (9.52 mm)
1/4" (6.35 mm)
CZ-4F5, 7, 10BP
1/2" (12.7 mm)
1/4" (6.35 mm)
CZ-52F5, 7, 10BP
5/8" (15.88 mm)
1/4" (6.35 mm)
Pipe size reducer (CZ-MA1P) for outdoor Multi connection CS-E12SD3UAW, CS-E18SD3UAW