Panasonic CS-E18SD3UAW service manual - Page 83
H33 Unspecified Voltage between Indoor and Outdoor
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
15.5.12 H33 (Unspecified Voltage between Indoor and Outdoor) Malfunction Decision Conditions The supply power is detected for its requirement by the indoor/outdoor transmission. Malfunction Caused Wrong models interconnected. Wrong indoor unit and outdoor unit PCBs used. Indoor unit or outdoor unit PCB defective. Troubleshooting When abnormality indication starts again Check indoor and outdoor units model number For safety reason and to prevent component breakdown, always switch Caution off the power before remove and connect the component. Is the indoor and outdoor unit model number matched? NO ● Match the compatible model (follow specification) Check indoor and outdoor PCB part number and compare if they matched part list. NO Change for the specified indoor or outdoor unit PCB. YES ● Replace the indoor and outdoor unit PCB. 83