Panasonic CS-E18SD3UAW service manual - Page 116
Piping Length Correction Factor
![]() |
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
18.3 Piping Length Correction Factor The characteristic of the unit has to be corrected in accordance with the piping length. 18.3.1 Cooling Capacity 18.3.1.1 CS-E9SD3UAW CU-E9SD3UA CS-12SD3UAW CU-12SD3UA Capacity Correction Factor 1.04 1.03 1.02 1.01 1.00 0.99 0.98 0.97 0.96 0.95 0 2 4 6 8 10 12 14 16 (6.6) (13.1) (19.7) (26.2) (32.8) (39.4) (45.9) (52.5) 3 (9.8) 5 (16.4) 7.5 (24.6) 10 (32.8) 15 (49.2) Pipe Length (m/ft) 18.3.1.2 CS-E18SD3UAW CU-E18SD3UA Capacity Correction Factor 1.02 1.01 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0 5 10 15 20 25 (16.4) (32.8) (49.2) (65.6) (82.0) Pipe Length (m/ft) 30 35 (98.4) (114.8) 3 (9.8) 5 (16.4) 7.5 (24.6) 10 (32.8) 15 (49.2) 20 (65.6) 30 (98.4) Note: The graphs show the factor after added right amount of additional refrigerant. 1.0334 1.0212 1.0000 0.9855 0.9629 1.0159 1.0076 1.0000 0.9889 0.9800 0.9746 0.9516 116