Panasonic CS-E18SD3UAW service manual - Page 71
refer to Error Codes Table by using Remote Control or Auto Switch at indoor unit. However,
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
Diagnosis display Abnormality / Protection control Abnormality Judgment Emergency Operation Primary location to verify F98 Total running current protection 3 times occurrence within 20 minutes F99 Outdoor Direct Current (DC) peak detection 7 times occurrence continuously Note: "O" - Frequency measured and fan speed fixed. ─ Excess refrigerant Improper heat radiation Outdoor PCB ─ IPM (Power transistor) Compressor The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until "beep" sound heard following by pressing the "CHECK" button at Remote Control. Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors (refer to Error Codes Table) by using Remote Control or Auto Switch at indoor unit. However, the Remote Control signal receiving sound is changed from one "beep" to four "beep" sounds. 71