Panasonic CS-E18SD3UAW service manual - Page 24
CU-E9SD3UA, CU-E12SD3UA
![]() |
View all Panasonic CS-E18SD3UAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
8.2 Outdoor Unit 8.2.1 CU-E9SD3UA CU-E12SD3UA SINGLE PHASE POWER SUPPLY TO INDOOR UNIT L1 YLW/GRN L2 1 2 3 (BLACK) (WHITE) (RED) TERMINAL BOARD BLK BLK WHT RED DATA (RED) WHT AC-BLK (BLK) COMMUNICATION CIRCUIT FUSE101 20A 250V NOISE FILTER CIRCUIT AC-WHT GRN (WHT) FG1 (GRN) GRN LJP101 (GRN) REMARKS BLK: BLACK BLU: BLUE FAN WHT: WHITE MOTOR RED: RED YLW: YELLOW M GRY: GRAY GRN: GREEN BRW: BROWN ORG: ORANGE YLW/GRN: YELLOW/GREEN 1 4 CN-DCFM (WHT) 7 YELLOW (YEL) ELECTRO-MAGNETIC COIL (EXPANSION VALVE) M REACTOR GRY RAT2 (GRY) GRY RAT1 (GRY) 1 CN-STM 6 (WHT) BLUE (BLU) RED (RED) (TRADEMARK) COMPRESSOR TERMINAL THE PARENTHESIZED LETTERS IS INDICATED ON TERMINAL COVER FUSE102 T3.15A L250V PFC CIRCUIT 1 CN-TH 2 (WHT) 3 4 RECTIFICATION CIRCUIT RECTIFICATION CIRCUIT CN-TANK 1 (WHT) 3 CN-HOT 1 (WHT) 2 FUSE103 T3.15A L250V Q1 P U V (RED) (BLU) N W (YLW) SWITCHING POWER SUPPLY CIRCUIT ELECTRONIC CONTROLLER AIR TEMP. SENSOR (THERMISTOR) t˚ t˚ PIPING TEMP. SENSOR (THERMISTOR) COMPRESSOR TEMP. SENSOR (THERMISTOR) t˚ YLW ELECTRO-MAGNETIC COIL (4-WAY VALVE) YLW RED BLU MS YLW 3~ COMPRESSOR Resistance of Compressor Windings MODEL CU-E9SD3UA/CU-E12SD3UA CONNECTION 5RS102XHA21 U-V 1.741 Ω U-W 1.765 Ω V-W 1.711 Ω Note: Resistance at 68°F of ambient temperature. 24