Panasonic CS-E18SD3UAW service manual - Page 36

Required Minimum Space for Installation and Service, Dimension of the Indoor Unit

Page 36 highlights

Required Minimum Space for Installation and Service 22 7/32" (564) Min. 7 7/8" (200) o r more 32 7/16" (824) (Suspension bolt pitch) Min. 7 7/8" (200) or more Electrical component box Inspection access 17 23/32" x 17 23/32" (450 x 450) Flange for air outlet duct Refrigerant tubing Min. 25 19/32" (650) or more Min. 25/32" (20) or more 7 7/8" (200) *H=Min. 9 7/16" (240) Min. 25/32" (20) or more Min 3 15/16" (100 mm) or more for bottom air intake Ceiling  H dimension means the minimum height of the unit installation space.  Select H dimension such that a downward slope of at least 1/100 is ensured. Refer to 11.1.4 "Connecting the drain piping" Dimension of the Indoor Unit 5 23/32" (145) 25 3/16" (640) 1 1/2" (38) 22 7/32" (564) (Suspension bolt pitch) 7 5/8" (194) 3 5/32" 5 5/8" 1 23/32" (44) (80) (143) 9 3/8" (238) 1 5/32" (29) 27 1/4" (692) (Flange for air outlet duct) 3 25/32" (96) 25 3/16" (640) (6 5/16" (160) x 4) 5-ø1/8" (ø3.1)(Hole) 2 5/8" (66) 1 1/32" (26) 1 1/16" (27) 1 3/32" (28) 1 3/16" (30) 2-ø1/8" (ø3.1) (Hole) 3 5/16" (84) 13/32" (10) 1 3/16" (30) 3 3/16" (81) Suspension lug Water inlet Inspection access 17 23/32" X 17 23/32" (450x450) (Field supply) 1 5/16" (33) 6 1/32" (153) 7/8" (22) 1 9/16" (40) 9/16" (14) 29 17/32" (750) 32 7/16" (824) (Suspension bolt pitch) 1 15/32" (37) 5 29/32" (150) 5 29/32" (150) 7 7/8" (200) 10-ø1/8" (ø3.1)(Hole) 6 3/32" (155) 4 23/32" (120) 9/16" (14) 9/16" (14) 29/32" (23) 19/32" (15) 26 25/32" (680) 5 3/16" (132) 29/32" (23) 8 21/32" 8 21/32" (220) (220) 27 23/32" (704) * Filter Uninstalled 5 3/16" (132) 29/32" (23) 36 4 31/32" (126)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

36
Required Minimum Space for Installation and Service
Flange for air outlet duct
32
7
/16" (
824) (Suspension bolt pitch)
Inspection
access
17
23
/32
"
x
17
23
/32
"
(
450 x 450)
Electrical
component box
Refrigerant tubing
Min. 25
19
/32
"
(
650) or more
Min. 7
7
/8"
(
200) or
more
22
7
/32
"
(
564)
Min.
7
7
/8
"
(
200)
or
more
Min.
25
/32" (20) or more
Min.
25
/32" (20) or more
7
7
/8
" (200)
*H=Min.
9
7
/16
" (240)
Min 3
15
/
16
" (100 mm) or more for bottom
air intake
Ceiling
H dimension means the minimum height of the unit installation space.
Select H dimension such that a downward slope of at least 1/100 is ensured. Refer to 11.1.4 “Connecting the
drain piping”
Dimension of the Indoor Unit
5
23
/32
" (145)
1
5
/32
" (29)
3
25
/32
"
(96)
2
5
/8
"
(66)
1
1
/32
"
(26)
1
1
/16"
(27)
1
3
/16
" (30)
1
3
/32
" (28)
3
5
/16
"
(84)
2-ø
1
/8
"
(ø3.1)
(Hole)
10-ø
1
/8
"
(ø3.1)(Hole)
1
3
/16
"
(30)
13
/32
"
(10)
3
5
/32
"
(80)
9
3
/8
" (238)
5
5
/8
"
(143)
Water inlet
1
23
/32
" (44)
3
3
/16
" (81)
1
5
/16
"
(33)
5
29
/32
" (150)
7
7
/8
" (200)
5
29
/32"
(150)
29
/32
"
(23)
5
3
/16
"
(132)
5
3
/16
"
(132)
8
21
/32
"
(220)
8
21
/32
"
(220)
27
23
/32
" (704)
29
/32
"
(23)
9
/16
" (14)
9
/16
"
(14)
9
/16
"
(14)
7
/8
"
(22)
26
25
/32
"
(680)
1
9
/16
"
(40)
6
3
/32
"
(155)
4
31
/32
"
(126)
25
3
/16
"
(640)
7
5
/8
" (
194)
6
1
/32
"
(153)
4
23
/32
"
(120)
27
1
/4
"
(692)
(Flange for air outlet duct)
1
15
/32
"
(37)
1
1
/2
"
(38)
29
/32
"
(23)
19
/32
"
(15)
Suspension lug
5-ø
1
/8
"
(ø3.1)(Hole)
25
3
/16
" (640) (6
5
/16
" (160) x 4)
Inspection access
17
23
/32" X
17
23
/32"
(450x450)
(Field supply)
22
7
/32
" (564) (Suspension bolt pitch)
32
7
/16
" (824) (Suspension bolt pitch)
29
17
/32
" (750)
* Filter Uninstalled